background image

Page  9/24 (37/21)

The shape of the head can change due to 
illness, growth or surgery - for a variety of 
reasons.
Thanks to its innovative design, the Star-
light

®

 Flex can be adjusted in many places 

and can thus be ideally adapted to the 
user‘s individual requirements.
You can rightly expect us - Europe‘s largest 
manufacturer of medical head protection 
- to consistently dispense with potentially 
dangerous metal parts, screws or the like 
that could cause head injuries to the user in 
the event of a fall, without compromising 
wearing comfort, multi-adjustability or the 
required protective effect! 

The device must be prescribed by a medical 
specialist, who has tested beforehand and 
determined if the Starlight

®

 Flex is suitable 

for the individual therapeutic goal of the 
patient. Furthermore, the medical special-
ist has determined the aid to be suitable 
according to measurements, weight and 
willingness of the patient to use the aid.
The aid is delivered via an authorised tech-
nician in compliance with the requirements 
of the country where it is being used and in 
strict accordance with the information and 
instructions in this manual for adjustments 
of the aid according to the measurements of 
the user. Only compliance of the regulations 
and instructions can lead to positive ergo-
nomically effects.
We wish you every success when using the 
head protection Starlight

®

 Flex.

•  Safety during independent movements 

and activities, for cerebral paretics, epilep-
tics and others at risk of falling.

•  Protection against increased injury poten-

tial in autoaggressive patients.

•  Protection against head injuries in the 

case of uncontrolled falling movements or 
movement sequences. 

•  Protection against fall hazards with 

increased potential of injury.

• 

Models with the top closed offers 
patients special protection, who for 
example have part of their skull cap 
missing.

The only contraindications to be mentioned 
here are possible skin intolerances to the 
materials used. 
We use selected materials for the processing 
of the head protection models that meet the 
highest quality standards.

Indications and prophylaxis

Purpose of use 

Indications and prophylaxis

Purpose of use

Summary of Contents for Starlight Flex

Page 1: ...User manual Head protection Starlight Flex Body protection edition 37 21...

Page 2: ......

Page 3: ...head protection Starlight Flex distinguishes itself by its quality security easy operation and modern design For optimal use of this aid we ask you and possible other users to carefully read this oper...

Page 4: ...se of use 10 8 Product overview 11 8 1 Basic model 11 8 2 Accessories Options 12 9 Initial operation 13 10 Assembly and adjustment 14 10 1 Basic model 14 10 2 Accessories Options 17 11 Types and acces...

Page 5: ...The user manual does not replace the experience of supervisory staff with the experience and knowledge of operators which they gained from for example training courses In the event of specific or diff...

Page 6: ...al without being bound to change previous devices and associated operating manuals Use of the rehabilitation aid and its accessories must be administered under medical supervision The head protection...

Page 7: ...glect through unauthorized alterations and modifications usage of non original spare parts or accessories through unpredictable and exceptional events resulting from non compliance of the regulations...

Page 8: ...end to non durable parts which are subject to normal wear and tear and need periodic replacement The warranty is null and void if non original ATO FORM parts accessories are used or if the product is...

Page 9: ...in compliance with the requirements of the country where it is being used and in strict accordance with the information and instructions in this manual for adjustments of the aid according to the meas...

Page 10: ...2 Ratchet closure for adjustment 3 Ear straps padded adjustable in length and inclination 4 Upper side anatomically shaped adjustable 5 Back head plate with Velcro tab for top attachment 6 Padding Inl...

Page 11: ...ion 3 Forehead protection 4 Chin protection 5 Sunshild 6 Alternative upper side head circumfer ence adjustable with velcro 7 Different fasteners without image 8 2 Accessories options For a complete ov...

Page 12: ...tail This way with help of the reseller the user as well as the attendant must become famil iar with the correct operation of the aid Once the demonstration has been complet ed the reseller must ensur...

Page 13: ...pad ding inlet must be loosen in the front area of the outer ring first for all adjustment options Setting the length of the ear straps and the ear cut out To adjust the length of the ear straps 3 de...

Page 14: ...a range of approx 4 cm on each side by means of the ratchet closure Do not adjust the head circumference too tightly after completing the settings the head circumference can be adjusted slightly usin...

Page 15: ...front and or sides and move them accordingly To adjust the height of the top in the rear area open the Velcro connection 6 on the back of the head 5 and replace the top 4 according to the desired sett...

Page 16: ...sides Fig 7 Inserting the padding inlet 1 6 Note The settings on your head protection are stabilised by the connection of the padding inlet to the outer ring Check that the padding inlet sits at the...

Page 17: ...he head protection should fit the head without tension or gaps The head protection is in the correct position when the head protection ring 1 see illustration sits exactly above the eyebrows and the b...

Page 18: ...buckle Types and Accessories 5555 01 Chin protection 5556 01 Fored protection with velcro 5557 01 Sunshild with velcro 11 Types and accessories 11 2 Accessories options 11 1 Basic model The most up to...

Page 19: ...ng Outer material Inlet Spacer fabric Filling Inlet High tech foam Product weight Basic model g approx 340 approx 360 approx 380 approx 400 Technical changes reserved Technical details 12 Technical de...

Page 20: ...rhaul 13 Cleaning and disinfection 14 Maintenance and overhaul The head protection should only be used if in a faultless condition Immediately contact your specialist dealer in case of any defects If...

Page 21: ...picture Re use A re use of the head protection series Starlight is excluded 15 Operating life and Re use Only original accessories and original spare parts may be used Non compliance with these instr...

Page 22: ...Page 22 24 37 21...

Page 23: ...ackaging parts are re useable The cardboard packaging is to be recycled as waste paper We therefore use paper as filler material Possible used plastic film of the packaging are made out of PE and are...

Page 24: ...mized solutions Thank you for your interest in our products For questions please contact ATO FORM GmbH or your specialist dealer Your ATO FORM Team ATO FORM GmbH Zur Lauterhecke 34 63877 Sailauf Germa...

Reviews: