background image

User Guide & General Maintenance

 

Rainier Summit R1 

18

1-888-MY-AIR11        CAG-06-21-002        AtmosAir.com

y

y

CLEAN AIR GROUP, INC. – PRODUCT WARRANTY 

Clean Air Group, Inc. d/b/a AtmosAir Solutions (“Clean Air Group”) warrants to the original purchaser of this product (“Customer”), 

that should it prove to be defective by reason of improper materials or workmanship, for 

twenty-four (24) months 

from the date 

of installation, or 

twenty-seven (27) months 

from the date of Clean Air Group’s delivery of the product, whichever occurs first, 

Clean Air Group shall repair or replace the product without charge to the Customer. Proof of malfunction and return of the non-

working product must be presented by the Customer if submitting a warranty claim. This warranty is invalid if the factory applied 

serial number has been altered or removed from the product. This warranty does not cover damage due to acts of God, misuse, 

abuse, negligence, or modification of or to any part of the product. This warranty does not cover damage due to improper 

installation, operation or maintenance, connection to improper voltage or electrical supply, or repair by anyone other than an 

authorized Clean Air Group service provider. To obtain warranty service the Customer must: (1) provide proof of purchase in 

the form of a Bill of Sale or receipted invoice, with evidence that the product is within the warranty period; (2) request a Return 

Merchandise Authorization (“RMA”) from Clean Air Group prior to shipping; and (3) ship the product with the RMA to Clean Air 

Group, freight prepaid, in either its original packaging or packaging affording an equal degree of protection. The product should 

be delivered to 

AtmosAir, 2115 East Cedar Street, Suite 6, Tempe, AZ 85281

. All transportation charges and shipping expenses 

are the Customer’s responsibility. Clean Air Group will return the product by the same method it receives the product. A product 

returned for repair after the warranty period, or that shows damage outside of the warranty coverage described herein, shall be 

repaired for a reasonable charge as determined by Clean Air Group. The Customer will be advised of the cost of repair or 

replacement before Clean Air Group proceeds.  

THE OBLIGATIONS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS, WHETHER 

EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND 

FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE TERM OF THE EXPRESS WARRANTY GRANTED HEREIN. 

Some states do not allow limitations on how long an implied warranty lasts, so the foregoing limitation or exclusion may not apply 

to you.  

With the exception of damages resulting from Clean Air Group’s failure to comply with any obligation under federal or state 

warranty laws, Clean Air Group SHALL NOT BE LIABLE TO THE CUSTOMER OR ANY OTHER PERSON OR THIRD PARTY 

FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO CONSEQUENTIAL, SPECIAL, INDIRECT, INCIDENTAL AND 

PUNITIVE DAMAGES AND/OR DAMAGES BY REASON OF INJURY TO ANY PERSON DUE TO ANY DEFECT OR 

MALFUNCTION OF THE PRODUCT OR ANY PART OR PARTS THEREOF OR FOR ANY OTHER REASON. This warranty 

gives you specific legal rights and you may have rights which vary from state to state.  If your product is defective please contact 

Clean Air Group or the dealer where you purchased the unit. 

Disclaimer: 

The air purification technology provided by AtmosAir is intended to improve air quality.  It is not intended to  replace 

reasonable precautions to prevent the transmission of airborne contaminants. Customer, its employees, invitees and all persons 

having access to the serviced premises should comply with all applicable public health laws and guidelines issued by federal, 

state and local governments and health authorities such as the Centers for Disease Control and Prevention (CDC). These 

precautions include but are not limited to wearing face masks, social distancing, hand hygiene and appropriate sanitizing and 

disinfecting. Clean Air Group does not assert that its products can protect people from viruses, bacteria or other airborne 

contaminants, expressly excludes liability for loss or damage arising from any such claims, and does not assume any liability for 

the consequences arising out of the application, use or misuse of its products, including any injury or damage to any person or 

damage to any property as a matter of product liability, negligence, contract or otherwise. 

Manufacturer, 

Anthony M. Abate 

Chief Technology Officer 

Clean Air Group, Inc. 

05 

PRODUCT WARRANTY

Summary of Contents for Rainier Summit R1

Page 1: ...te where no pollution or contaminants exist The Rainier s patented active ionization technology has been rigorously tested and scientifically proven to be extremely effective at reducing harmful parti...

Page 2: ...er Replacement Filter Replacement Filter Replacement Filter Replacement Filter Replacement Filter Replacement Filter Replacement Filter Replacement Tube Replacement enter date 3 months from above ente...

Page 3: ...booklet before beginning the maintenance Follow each maintenance step exactly as shown and explained in this guide Observe all local state national and international electrical codes Pay close attenti...

Page 4: ...osing Location 5 Unit Setup 5 02 GENERAL USE GUIDELINES 6 Unit Settings 6 Unit Settings Continued 7 Room Conditions 7 Care and Handling 7 Maintaining Your Unit 7 Maintaining Your Unit Continued 8 03 T...

Page 5: ...et 37 m2 at 2 air changes per hour for spaces such as large bedrooms offices kitchens family rooms etc The best place to locate the unit is 4 to 7 1 2 to 2 1 meters off the floor in a central area wit...

Page 6: ...It is always recommended to keep the Fan Speed at full power or fully clockwise as this will allow the system filter to trap the most dirt and the bi polar ions to be projected out into the room for o...

Page 7: ...operating at top performance and trouble free Failure to follow the recommended maintenance intervals may result in premature wear of the unit and system failure which will not be covered by manufactu...

Page 8: ...with the new filter Be sure to place the new filter in snugly and to note you are placing the filter in the correct orientation by noting the airflow direction arrow on the side of the filter Inside t...

Page 9: ...ave been checked and a blown fuse is causing the malfunction Note If all the above steps have been performed and the unit still will not power on contact the reseller you purchased your unit from for...

Page 10: ...CONTROL KNOBS OR INDICATIOR LIGHT THE ROTARY KNOBS AND SWITCHES WILL IMMEDIATELY BE DAMAGED AND NOT COVERED UNDER WARRANTY Either gently lay the unit on a rag piece of thick foam and let the knobs pro...

Page 11: ...moved in order to open the unit They are located on the right and left side of the unit towards the bottom 3 Place the unit standing upright on one of its sides preferably on a towel or foam pad in or...

Page 12: ...H TOO MUCH FORCE OR YOU MAY DAMAGE THE WIRES ON THE CONTROL KNOB SWITCHES 6 Once all four screws have been removed with the unit still on its side turn the back of the unit to face you 7 Using one han...

Page 13: ...unit so that the ionization tube is facing you 10 To remove the tube use one hand to gently hold back the metal spring tang 11 With the other hand hold the plastic cap of the tube and spin the tube ou...

Page 14: ...he tube into the tube holder Do not grab the glass or the screen Do not torque on the glass 15 Tighten carefully using the blue cap Tighten until the nut on the tube screw is contacting the metal tab...

Page 15: ...com 17 Check that the spring tang is lying flat against the screen without edge contact as shown under step 18 18 Needle Nose Pliers can be used to adjust the spring tang to lay flat against the surf...

Page 16: ...com 19 The unit is now ready to be reassembled Begin by gently sliding the two halves of the chassis together taking care not to pinch any wires between the metal parts 20 Tuck the black part of the...

Page 17: ...holes use a Phillips no 2 screwdriver to start screwing in the two screws in one side but leave them loose Do not tighten them all the way until ALL screws have been inserted 22 Turn the unit over an...

Page 18: ...S OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURP...

Reviews: