User Guide & General Maintenance
Rainier Summit R1
10
1-888-MY-AIR11 CAG-06-21-002 AtmosAir.com
04
TUBE REPLACEMENT
This is the procedure for replacing the glass ‘B’ Sized tube in an AtmosAir Rainier R1/R2 ionization unit.
At the end of its service life, the ionization tube
must be replaced
in order to keep the ionization unit working correctly. The End
user must remove the old tube and install a new, genuine AtmosAir ionization tube.
CAUTION! DO NOT LAY THE RAINIER DOWN ON ITS CONTROL KNOBS OR INDICATIOR LIGHT. THE ROTARY KNOBS AND
SWITCHES WILL IMMEDIATELY BE DAMAGED AND NOT COVERED UNDER WARRANTY.
Either, gently lay the unit on a rag/piece of thick foam and let the knobs protrude over a tabletop. Or prop the unit up on a suitable
spacer like wooden 2x4’s to assure
no weight is put on the knobs
.
Items you will need:
■
New AtmosAir MCG glass tube ‘B’ size
■
Phillips no. 2 screwdriver
■
Needle nose pliers
■
Recommended - Towel or foam pad to avoid scratching work surface or ionization unit
Procedure
1.
Ensure the unit is
turned off
and
unplugged
before continuing.
Never
attempt to service the unit while it is plugged in and
or turned on.