14
5.0 Maintenance
•
Annual service inspection for the ATMOS Aqua clean with
service kit (service interval is also dependent on water
hardness!) This service contains a complete function
control of the device, exchange of the input fi lter (Fig.
21), test (if required exchange) of the water dosing valves
(Fig. 22) and magnetic valves , the water non-return
valve (Fig 22) as well as the tubes (Fig 22). Additio-
nally, also an inspection (and if required cleaning) of the
mixing container (Fig. 22) and its probes needs to be
carried out.
•
The safety-related checks acc. to IEC 62353 must be
performed at least every 12 months.
•
ATMOS cannot guarantee perfect functioning neither will
it be liable for damage to people or property if:
•
any non-original ATMOS parts are used,
•
the user instructions given in this manual are not
followed exactly or are disregarded,
•
assembly, resetting, alterations, extensions and
repairs are not carried out by people authorised by
ATMOS.
•
No warranty rights shall exist in the event of damage or
failure caused by the use of non-ATMOS accessories or
non-ATMOS consumables.
•
Check hoses and connections on any leakages at regular
intervals.
•
Prior to sending in the device for repair it must be fully
emptied.
•
For an extensive fi nal inspection of the device during
repair, please include all accessories into the delivery.
5.1 Regular inspections
•
Functional and tidiness inspections are required after any
work at the ATMOS Aqua clean. Safety-related inspec-
tions are to be performed along with the inspection of the
connected treatment unit or at least once a year (acc. to
BGVA3). Furthermore the control and safety functions
must be checked.