18
6.1.2 Retrofi tting of a delay PCB
●
Drilling of the holes for the fi xing bolts. Place the PCB on the carrier
plate and mark the drillings. Afterwards drill the holes with a 3.5 mm
drill.
●
Screw the 4 bolts M3x10 including washer and locknut.
●
Tighten the PCB with 4 lens head screws 3x5.
●
Fix the connecting cable (REF 530.2124.0) as per the drawing.
●
Connect the existing Aquastop to the PCB, REF 011.1314.0.
6.0 Retrofi tting
Fig. 25
Fig 26