background image

Atlona Manuals 

Dante IP Bridge

AT-OMNI-232

Summary of Contents for OmniStream AT-OMNI-232

Page 1: ...AtlonaManuals DanteIPBridge AT OMNI 232...

Page 2: ...AT OMNI 232 2 Version Release Date Notes 1 04 28 Initial release Version Information...

Page 3: ...the product warranty To register your product go to http www atlona com registration As of this writing there are no firmware updates for this product When new firmware is released update instructions...

Page 4: ...uct Warranty Terms New Products 10 years from proof of purchase date for hardware electronics products purchased on or after June 1 2013 3 years from proof of purchase date for hardware electronics pr...

Page 5: ...s or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or excl...

Page 6: ...Do not use this product near water 6 Clean only with a dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install or place this prod...

Page 7: ...Connection Instructions 10 Connection Diagram 11 Mounting Instructions 12 Configuration 13 IP 13 DHCP mode 13 Auto IP mode 13 Static IP mode 13 Dante Controller 13 AMS 14 System Info 15 Channel Setti...

Page 8: ...Power over Ethernet PoE as well as from local AC power The AT OMNI 232 extends the power and flexibility of the OmniStream networked AV platform by enabling facility wide system designs that include c...

Page 9: ...cator is green when the unit is powered 2 DC 24V Connect optional power supply AT PS 24250 L for an alternative power source 3 ETHERNET Connect to a PoE switch for power and signal distribution 4 LINE...

Page 10: ...ns may be used 1 Use wire strippers to remove a portion of the cable jacket 2 Remove at least 3 16 5 mm from the insulation of each wire 3 Insert the wires into the correct terminal on the included Ph...

Page 11: ...0 0 G 2 Audio Amplifier DEVI CE STAT US PRES ET CON F ROO M 1 AT D SP 4 81 OK STAT US U S B U S B POW ER SET PWR DSP Hi gh D en sit y AE S Pr oc es so r AT OMNI 232 AT OMNI 112 Display AT OMNI 121 AT...

Page 12: ...provide added stability to the rack ear use two of the included screws and attach them to the two holes directly below the enclosure screws as shown below 1 Repeat steps 1 through 4 to attach the sec...

Page 13: ...switching Dante Controller is needed To download the software go to http www audinate com The software will be found under products software Dante Controller The download button is found on the right...

Page 14: ...en click the Login button Note that the password is masked when typed Login admin Password admin123 AMS is used for adjusting device settings such as input volume output volume phantom power and updat...

Page 15: ...mDNS Discovery e After the mDNS listener is enabled click the OK button to dismiss the message box f The OMNI 232 should now be listed under the Domain View pane AMS IMPORTANT OmniStream uses mDNS as...

Page 16: ...ut volume Settings are from 60 to 0 Mute Select the checkbox to mute or unmute the output volume Blink Timer Sets the amount of time the front panel PWR LED will blink for This helps to find the corre...

Page 17: ...carriage return If the command fails or is incorrect the feedback should be NACK command Unit Command Description Blink Blinks the power LED on the unit s front panel Blink ms Sets how long the front...

Page 18: ...Syntax Blink X Syntax Blink Xms Parameter Description Range X State 0 off 1 on Parameter Description Range X Duration up to 65 535 Feedback ACK Blink 1 Feedback ACK Blink 30000ms GetMAC Displays the...

Page 19: ...plays the settings of the unit Example Query Syntax Query Feedback ACK Query VIN1 VIN2 VOUT1 VOUT2 VOUTMute1 VOUTMute2 MicPP1 MicPP2 Blink Feedback ACK Mreset Mreset Sets the unit back to factory defa...

Page 20: ...turn If the command fails or is incorrect the feedback should be NACK command Audio Command Description MicPP Turns phantom power on off for each input Recall Loads the previously saved settings Save...

Page 21: ...to 9 Feedback ACK Save 3 MicPP Turns phantom power on off for each input Example MicPP 1 1 Syntax MicPP X Y Parameter Description Range X Channel 0 both 1 2 Y State 0 off 1 on Feedback ACK MicPP 1 1...

Page 22: ...annel 0 both 1 2 Y Level 60 to 0 VOUTMute Mutes unmutes the output audio channels Example VOUTMute 0 1 Syntax VOUTMute X Y Parameter Description Range X Channel 0 both 1 2 Y State 0 off 1 on VIN Adjus...

Page 23: ...20 kHz 5dB Input Impedance 1 8 k Phantom Power 24V Noise THD N 0 015 from 20 Hz to 20 kHz 45 dB gain SNR 90 dB unweighted Distance Max distance dependent on Network configuration Temperature Fahrenhei...

Page 24: ...OMNI 232 24 Appendix Dimensions Inches Millimeters H x W x D 1 06 x 6 46 x 3 46 27 x 164 x 88 Weight Pounds Kilograms Device 0 82 0 37 Certification Power Supply CE FCC cULus RoHS CCC RCM Product CE F...

Page 25: ...ustomer support 3 D Dante Controller 13 F FCC statement 6 Features 8 Feedback command 17 20 Firmware version 15 I Installation 10 IP auto 13 DHCP 13 static 13 M MAC address 15 18 MIC Phantom Power 10...

Page 26: ...registered trademarks of Atlona Inc All other brand names and trademarks or registered trademarks are the property of their respective owners Pricing specifications and availability subject to change...

Reviews: