Network:

 IP address, netmask, gateway, and telnet port can be set to any settings compatible 

 

      with your network. The Netmask and Gateway must match your existing network 

 

      settings

     IP Mode -
 

Static: Set a fixed IP address

 

Note: 

For a stable connection when using a control system, it is best to set up a static IP. As you select 

 

          an IP address, make certain no other devices on your network are using that IP address

 

DHCP: Dynamic Host Configuration Protocol will automatically select an IP address 

 

 

  on the network that is not already in use

     Telnet Login Mode - Turn on/off - requires a password to adjust settings
     Telnet Timeout - Set the auto log-off time between 1 and 3600 seconds
     Broadcast - Turn on and off the feedback through all control ports

     Power - Turns the unit on/off
     Lock - Locks or unlocks the front panel buttons
     Power button mode - Set the power button to turn the device, display 

(via CEC)

, or both on/off

     Reset to Default - Reset the device to factory settings
     Firmware Update - Use this feature to find and load the MCU firmware to the switcher 

 

Note:

 Firmware can be found and downloaded from http://www.atlona.com/product/AT-CAT-4ED/ page 

 

          under the firmware tab

     Valens Update - Use this feature to find and load the Valens firmware to the Valens chips

Summary of Contents for AT-UHD-CAT-4ED

Page 1: ...6 3976 Local 1 408 962 0515 4K UHD 4 Output HDMI to HDBaseT Extended Distance Distribution Amplifier Please check http www atlona com product AT UHD CAT 4ED for the most recent firmware update or manu...

Page 2: ...ack mounts 4 5 Panel Descriptions a Front Panel 4 b Back Panel 4 6 Category cable 5 7 TCP IP and GUI 6 10 8 RS 232 a Connection 11 b Set Up 11 c Commands 12 13 9 IR 13 10 Connection Diagram 14 11 Cont...

Page 3: ...a 1U half rack width enclosure with external international power supply Package Contents Features 1 x AT UHD CAT 4ED 5 x Female captive screw connectors RS 232 and IR 1 x Short rack ear 1 x Long rack...

Page 4: ...rk router for control 2 Master control Connect to PC or control system for unit control 3 RS 232 IR control ports Connect to PC or control system for zone control 4 FW port Connect to a PC for firmwar...

Page 5: ...causing loss of signal Important EZ RJ45 connectors are not recommended with HDBaseT extenders Doing so may result in interference with audio and video transmission Use the table below to verify the...

Page 6: ...or firewall that may interfere with network communication to the switcher Once set up is done and the switcher GUI is no longer being used the firewall and anti virus can be re enabled For convenienc...

Page 7: ...information RS 232 Parameter Setting Zone These settings have no effect on RS 232 operation and are simply passed through Console Adjust the RS 232 parameters of the UHD CAT to make it compatible with...

Page 8: ...ve the ability to access this page Admin password can also be changed Be sure to write this information down as admin is the only profile allowed to add remove users Note Default username root and pas...

Page 9: ...the network that is not already in use Telnet Login Mode Turn on off requires a password to adjust settings Telnet Timeout Set the auto log off time between 1 and 3600 seconds Broadcast Turn on and o...

Page 10: ...Vs Many manufacturers do not support the CEC Off command when sent from a source and older TVs use proprietary commands Atlona only supports those TVs that follow CEC command structure from HDMI 1 2a...

Page 11: ...e port settings tab and update the menu to the CAT 4ED default settings of Bits Per Second 115200 Data Bits 8 Parity None Stop Bits 1 and Flow Control None see picture C Set up is done and any hyperte...

Page 12: ...aseT output 1 to memory EDIDMSet X EDIDMSet X Set the Internal EDID X 0 16 sta HDCPSet X HDCPSet X Switch the EDID reporting between Compliant on and non compliant off Blink Blink Will blink an LED on...

Page 13: ...telnet port 80 IPPort 80 IPLogin Y IPLogin Y IPLogin on off sta Set telnet login status e g Set telnet login is on IPLogin on Broadcast Y Broadcast Y Broadcast on off sta Broadcast switch e g Set broa...

Page 14: ...4 RELAYS WIFI 2 ZIGBEE 12V DC IR OUT ID FACTORY RESTORE SERIAL 1 SERIAL 2 HDMI COMPONENT VIDEO OUT ETHERNET CONTACTS AUDIO OUT AUDIO IN WIFI 1 eSATA DIGITAL COAX OUT 1 2 3 4 5 6 L R AT UHD CAT 4 Cont...

Page 15: ...os DTS X Sample Rate 32kHz 44 1kHz 48kHz 88 2kHz 96kHz 176 4kHz 192kHz Bit Rate up to 24 bit Distance CAT5e 6 4K up to 70M up to 230 ft CAT6a 7 4K up to 100M up to 328 ft CAT5e 6 1080p up to 100M up t...

Page 16: ...tanks and swimming pools Use only accessories recommended by Atlona to avoid fire shock or other hazards Unplug the product before cleaning Use a damp cloth for cleaning and not cleaning fluid or aer...

Page 17: ...for all cable products Limited Product Warranty Terms Refurbished B Stock Products 3 years from proof of purchase date for all Refurbished B Stock hardware and electronic products purchased on or aft...

Page 18: ...r any other legal theory Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to sp...

Reviews: