13
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Command
Feedback
Description
IPCFG
IP Addr : x.x.x.x
Netmask : x.x.x.x
Gateway : x.x.x.x
IP Port : x
Displays IP address configure
IPQuit
IPQuit
Telnet Logout
IPAddUser X Y
IPAddUser X Y
IPAddUser [name] [password]. Add user of telnet.
If only command write “IPAddUser”, it will display all user list.
=> IPAddUser
IPDelUser Y
IPDelUser Y
IPDelUser [name]. Del user of telnet
IPDHCP Y
IPDHCP Y
IPDHCP [on/off/sta]. Set DHCP mode status and auto reset telnet.
e.g.
Set DHCP mode is on => IPDHCP on
IPStatic X Y Z
IPStatic X Y Z
IPStatic [Address] [Netmask] [Gateway]. Set static IP address and
auto reset telnet.
e.g.
Set static IP address is 192.168.1.1 255.255.255.0 192.168.1.254
=> IPStatic 192.168.1.1 255.255.255.0 192.168.1.254
IPPort Y
IPPort Y
IPPort [port]. Set telnet port and auto reset telnet
e.g.
Set telnet port 80 => IPPort 80
IPLogin Y
IPLogin Y
IPLogin [on/off/sta]. Set telnet login status.
e.g.
Set telnet login is on => IPLogin on
Broadcast Y
Broadcast Y
Broadcast [on/off/sta]. Broadcast switch.
e.g.
Set broadcast mode is on => Broadcast on
IPTimeout Y
IPTimeout Y
IPTimeout [Sec]. Set telnet idle timeout time. Default is 2 minute.
e.g.
Set telnet idle timeout 10 minutes => IPTimeout 600
Each command is terminated with a carriage return.
Feedback is terminated with a carriage return and line feed.
Note:
If the command fails or is incorrect the feedback should be “Command FAILED”
IP Commands
IR
System IR is typically used to connect to control system processors. This input is used to control the
UHD-CAT.
Note:
The IR receiver is optional for the UHD-CAT. The compatible IR receiver (AT-IR-CS-RX) can be purchased
through atlona.com.
The wires of the emitter
(TX)
and receiver
(RX)
have been marked to differenciate the pin outs.
The included IR emitter has two wires: TX and ground. Signal
(TX)
will have a solid line and ground
will be blank.
Signal (TX)
Ground (
)