9.2. RS232 Cable Wiring
AT-PROHD85M-SR
Remote c
ontrol
device
Pin
Pin
1
NC
1
NC
2
Tx
2
Rx
3
Rx
3
Tx
4
NC
4
NC
5
GND
5
GND
6
NC
6
NC
7
NC
7
NC
8
NC
8
NC
9
NC
9
NC
9.3. RS232 Commands:
Note: ‘ ’ is carriage return.
OUTPUT
COMMAND
ACTION
Output 1
cir 00
Output 1 select Input1
cir 01
Output 1 select Input2
cir 02
Output 1 select Input3
cir 03
Output 1 select Input4
cir 04
Output 1 select Input5
cir 05
Output 1 select Input6
cir 06
Output 1 select Input7
cir 07
Output 1 select Input8
Output 2
cir 10
Output 2 select Input1
cir 11
Output 2 select Input2
cir 12
Output 2 select Input3
cir 13
Output 2 select Input4
cir 14
Output 2 select Input5
cir 15
Output 2 select Input6
cir 16
Output 2 select Input7
cir 17
Output 2 select Input8
Output 3
cir 20
Output 3 select Input1
cir 21
Output 3 select Input2
cir 22
Output 3 select Input3
cir 23
Output 3 select Input4