AT-ETU-SYNC
13
LED/Button
State
Description
LEARN
Flashing blue
EDID being learned.
Off
EDID learned successfully.
Flashing red
Error learned EDID.
•
Bad or corrupt EDID on sink.
• No sink device present or detected.
• Make sure sink is powered.
•
Check for proper connection between sink device
and
AT-ETU-SYNC.
•
Possible bad cable.
HPD
Solid green
Sink device OK.
Off
Sink device not detected.
During the process, the
LEARN
button will flash blue as the EDID data is copied into memory.
If the EDID was successfully learned, then the
LEARN
button will turn off. If an error was encountered during the
operation, then the
LEARN
button will flash red.
If an error is encountered, disconnect the power from the AT-ETU-SYNC, power-cycle the sink device, then
repeat steps 4 through 6. If after several attempts, the error is encountered, then this may indicate that the sink
device has a bad or corrupt EDID.
7.
Reconnect the source (or other intermediate device) to the
HDMI IN
port on the AT-ETU-SYNC. The source will
read the EDID data stored in EDID mode 0 and use this information to send the proper audio and video formats
to the sink device.
Flashes blue while learning EDID
NOTE:
EDID data will remain in EDID mode 0, even after power is disconnected. To learn a new EDID
and overwrite the existing EDID data in mode 0, repeat steps 1 through 6.
Basic Operation