background image

©20

19 

Atlas Sound LP

. T

he 

Atlas 

“Circle 

A”

, Soundolier

, and 

Atlas Sound are trademarks of 

Atlas Sound L.P

. IED is a R

egistered 

Trademark of Inno

vativ

e Electronic Designs LLC. 

All rights reser

ved. 

 

All other 

Trademarks are propert

y of their respectiv

e o

wners. No endorsement is implied. Due to continual product de

velopment, specifications are subject to c

hange without notice. 

ATS0

05966 R

evA 5/1

9 D

OC1

227B

AtlasIED.com

TELEPHONE: (502) 267-7436

[email protected]

9701 TAYLORSVILLE ROAD 

LOUISVILLE, KENTUCKY 40299 U.S.A.

 

  

WARNING - When The Device Is In Use

  

 

•  WARNING: For the terminals marked with symbol of        may be of sufficient magnitude to constitute a risk of electric shock. The external wiring    
 

connected to the terminals requires installation by an instructed person or the used of ready-made leads or cords.

•  WARNING: The apparatus shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on  

 

 apparatus. 
•  WARNING: The mains plug is used as disconnect device, the disconnect device shall remain readily operable.
•  To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to AtlasIED. 
•  Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and  

 

 

contact AtlasIED. Do not to attempt to continue operation with the product as this may cause fire or electric shock:

 

•  Smoke or strange smell coming from the unit.

 

•  If the product falls or the case is damaged.

 

•  If water or any metallic objects falls into the product.

 

•   If the power supply cord is damaged in any way.

 

•  If the unit is malfunctioning.

• 

Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in electric shock or   

 fire.
• 

Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric shock may result.

• 

Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.

• 

Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result. 

• 

Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used. 

• 

Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects on the power    

 

cord, including the product itself, doing so may result in fire or electrical shock. 

• 

Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic disaster may  

 

 result. 
• 

Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property damage.

 

  

CAUTION - When Installing The Product

 
•   Plugging in or unplugging the power cord with wet hands may result in electric shock. 
•  Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.  
•  When unplugging the cord from the wall, grasp the plug, NOT the cord. 
•  Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or steam are  

 

 

present. Fire and electric shock may result.

•  Keep all sides of the unit at least 3

1

/

2

" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.

 

  

CAUTION - When The Product Is In Use

 
•  Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In addition, the product    
 

itself may fall and cause injury and property damage. 

•  Contact AtlasIED for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat buildup and fire. 
•  Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or inside the wall  

 

 outlet. 
•  When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.

Summary of Contents for 1544ZOP

Page 1: ...er Trademarks are property of their respective owners No endorsement is implied Due to continual product development specifications are subject to change without notice ATS005966 RevA 5 19 DOC1227B AtlasIED com TELEPHONE 502 267 7436 SUPPORT ATLASIED COM 9701 TAYLORSVILLE ROAD LOUISVILLE KENTUCKY 40299 U S A 4x4 Smart Zone Output Processor 1544ZOP Installation Manual Version 0 3 Document 1227B ...

Page 2: ...ns are subject to change without notice ATS005966 RevA 5 19 DOC1227B AtlasIED com TELEPHONE 502 267 7436 SUPPORT ATLASIED COM 9701 TAYLORSVILLE ROAD LOUISVILLE KENTUCKY 40299 U S A Table of Contents Important Safety Instructions 3 Introduction 8 Key Features 8 Front Panel Description 9 Rear Panel Description 9 Installing the 1544ZOP 10 Connecting Supervised Logic Inputs 11 Connecting Unbalanced Au...

Page 3: ...for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 This product is equipped with a three wire groundi...

Page 4: ... or electric shock may result Never operate this product or touch the power supply cord during an electrical storm electric shock may result Never exceed the power rating on the product when connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not modify kink ...

Page 5: ...ecautions Personnel properly qualified in the application and use of life safety equipment qualified personnel shall read this manual carefully before performing any actions to specify apply install maintain and perform operational tests of AtlasIED systems and associated products in accordance with the instructions in this manual This manual shall be made available to all qualified personnel who ...

Page 6: ...nd performed only by qualified personnel Whenever operation and maintenance is ongoing personnel in the equipment areas shall have an effective communication among these areas in order to protect people if any accident occurs Preliminary Precautions Precautions which are applicable to general electrical or electronic maintenance are as follows A Check yourself Wear no article that might catch on e...

Page 7: ...sement Vérifier d abord si il y a un réseau de purgeur incorporé Si c est le cas attendez une minute ou deux pour que le condensateur se décharge par le réseau Sinon utilisez un réseau de décharge externe Ceci est très important en cas de haute tension ou des condensateurs à haute capacité Si un terminal est relié à la terre connecter le réseau de décharge entre l autre terminal et la terre Si auc...

Page 8: ...four balanced line level analog inputs that may be used as automated test inputs associated with the four zone outputs Alternately the analog inputs may be routed out over the network as Dante digital audio for such uses as for background music or auxiliary audio sources The 1544ZOP also provides eight 8 logic inputs Four of the inputs are standard closure detection and four are supervision capabl...

Page 9: ...nd B per channel may be connected If only one sensor is used per channel it can go into either the A or B position for the channel 2 Standard Logic Inputs These four inputs only detect open or closed circuit connections such as from dry contact closures Wetting voltage for inputs are supplied internally 3 Supervisable Logic Inputs These four inputs can be configured to detect shorts and opens in t...

Page 10: ...ny accompanying components that may have been included The unit comes with a PA702 RMK kit of rack ears blank spacer and joining clips for easy mounting into a 19 rack The components of the rack mount kit are shown in the figure below The unit may be mounted either singly in a 19 rack using blank spacer and rack ears The unit can also be combined with a second 1544ZOP or compatible half rack unit ...

Page 11: ...ced Audio Inputs Outputs The analog audio inputs outputs on the 1544ZOP are balanced On occasion it may be necessary to connect unbalanced audio devices to the 1544ZOP When doing this one should wire as shown in the figure below Connecting a Power Supply A suitable power supply should be connected to the rear connector being careful to observe the polarity shown on the connector Suitable power sup...

Page 12: ...reen LED on Front Fault LED Yellow Amber LED on Front Network Connection LED Yellow LED on RJ 45 Connectors on Rear Network Data LED Green LED on RJ 45 Connectors on Rear Electrical Frequency Response 0 3 dB 20 Hz 20 kHz Unweighted Total Harmonic Distortion THD 0 01 20 Hz 20 kHz Unweighted Signal to Noise Ratio 90 dB 20 Hz 20 kHz Unweighted Line Level Inputs 6 dBu Max Line Level Outputs 6 dBu Max ...

Page 13: ...ns 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equ...

Page 14: ... when products have been modified or operated in excess of rated power altered serviced or installed in other than a workman like manner The original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to AtlasIED do not qualify for repair or replacement under our w...

Reviews: