background image

1.Safety precautions

1.1 General security

Statement

When installing, operating and maintaining the equipment, please read this manual 

first and follow the signs on the equipment and all safety precautions .

The “notice", "attention", "warning" and "danger" in the manual do not represent all 

safety precautions to be observed, but only supplement all safety precautions. The 

company shall not be liable for any violation of general safety operation requirements 

or safety standards for design, production and use of equipment.

The equipment shall be used in an environment that meets the requirements of design 

specifications, otherwise it may cause equipment failure, and the resulting equipment 

function abnormalities or component damage, personal safety accidents, property 

losses, etc. are not within the scope of equipment quality assurance. The installation, 

operation and maintenance of the equipment shall comply with local laws, regulations 

and specifications. The safety precautions in the manual are only a supplement to local 

laws, regulations and specifications.

The company shall not be liable for any of the following circumstances.

 Do not operate under the service conditions described in this manual. 

 

 

The installation and use environment exceeds the provisions of relevant

    international or national standards.

 

Disassemble, change the product or modify the software code 

    without authorization.

 

Failure to follow the operation instructions and safety warnings in the product 

    and documents.

 Transportation damage caused by customer's own transportation.

 Damage caused by storage conditions not meeting the requirements 

    

of product documents.

General requirements

Live operation is strictly prohibited during installation.

 

It is strictly prohibited to install, use and operate outdoor equipment and cables 

    (including but not limited to handling equipment, operating equipment and 

    cables, plug and unplug signal interfaces connected to outdoor, high-altitude 

    operation, outdoor installation, etc.) in severe weather such as lightning, rain, 

    snow and force gale.

 After installing the equipment, the empty packaging materials such as cartons, foam, 

    plastic, tie line should be removed.

 In case of fire, evacuate the building or equipment area and press the fire alarm bell 

    or dial the fire alarm telephone. Under no circumstances shall re-enter the burning 

    building.

 

It is strictly prohibited to artificially alter, damage or block the identification and 

    nameplate on the equipment. 

DANGER

1

Summary of Contents for LiFePO4

Page 1: ...Wall Mounted Household Energy Storage Series User Manual LiFePO4 ...

Page 2: ...ings Symbol Explanation Indicates a hazard with high risk that will lead to death or serious injury if not avoided Indicates a hazard with medium risk that may lead to death or serious injury if not avoided Indicates a hazard with low level risk that may cause slight or moderate injury if not avoided It is used to transmit equipment or environmental safety warning information If not avoided it may...

Page 3: ...14 8 Battery storage requirements 34 5 2 4 Indication description 22 4 4 Battery connection 14 4 4 1 Single battery connection 14 5 2 1 Screen 18 6 1 Software running environment 27 9 Warranty products 35 4 1 Cable connection 12 6 3 Interface function 28 6 3 4 Parameter setting 31 10 Exemption from liability 35 6 3 2 Parallel monitoring 30 5 2 3 RST key description 21 4 2 communication line connec...

Page 4: ... not operate under the service conditions described in this manual The installation and use environment exceeds the provisions of relevant international or national standards Disassemble change the product or modify the software code without authorization Failure to follow the operation instructions and safety warnings in the product and documents Transportation damage caused by customer s own tra...

Page 5: ...Before using the tool please master the correct use method of the tool to avoid personal injury and equipment damage When the equipment is running the shell temperature is high and there is a risk of burns Do not touch it In case of battery failure the temperature may exceed the burn threshold of the touchable surface and contact should be avoided Do not open or damage the battery The released ele...

Page 6: ...k medical help immediately Fire treatment measures In case of fire the system should be powered off under the condition of ensuring safety Use carbon dioxide FM 200 or ABC dry powder fire extinguisher to extinguish the fire When the battery temperature is too high it will cause battery deformation damage electrolyte overflow and toxic gas leakage Please keep away from it to avoid skin irritation a...

Page 7: ...xperience can be aware of the risks that may be brought to him during a certain operation and can take measures to minimize the risks to himself or other personnel Operators operators who may come into contact with the equipment other than trained personnel and professionals Explanation Before making electrical connection please ensure that the equipment is not damaged otherwise electric shock or ...

Page 8: ...store and release electric energy according to the requirements of inverter management system The input and output ports of wall mounted household energy storage series are 48 51 2V DC Battery charging the power control module is connected with the energy storage terminals BAT bat of the inverter to charge the battery and store the excess photovoltaic energy in the battery under the control of the...

Page 9: ...tery Nagetive terminal Handle Handling Reset key On OFF button ADS Dialer Display connection address Dry contact 1 2 Normally open closed during fault protection 3 4 Normally open closed when a low battery alarm signal has occurred RS485 RS485 communication interface CAN CAN communication interface RS232 RS232 communication interface for battery condition monitoring RS485 RS485 communication inter...

Page 10: ...lly open closed during fault protection 3 4 Normally open closed when a low battery alarm signal has occurred RS485 RS485 communication interface CAN CAN communication interface RS232 RS232 communication interface for battery condition monitoring RS485 RS485 communication interface Used in communication parallel and for battery condition monitoring or manufacturer to debug or service RS485 MCB Out...

Page 11: ...m include The inverter is connected through RS485 interface and can interface to realize the communication and control between the inverter and wall mounted energy storage system Connect the battery directly through the mobile phone Bluetooth app to view manage and maintain the wall mounted energy storage system Access the public network through WiFi and the management system will view manage and ...

Page 12: ...40 Expansion screws M8 MSDS Transportation certificate RS232 communication line Power line 1m Parallel line Customized according to customers RS485 communication line Customized according to customers H MSDS A B C D E F G 3 2 Basic installation requirements It shall be installed in a dry and well ventilated environment to ensure good heat dissipation It is recommended to choose a sheltered install...

Page 13: ...en the battery is running do not block the vent or cooling system to prevent high temperature fire Battery operating temperature charging 0 55 discharging 20 60 It is forbidden to put the battery in the environment of flammable explosive gas or smoke and any operation in this environment is prohibited The battery can be installed on a vertical or backward inclined plane Please refer to the followi...

Page 14: ...tom Ensure that the center of gravity of the body does not deviate from the edge of the ladder 3 4 Drilling safety The following safety precautions shall be considered when drilling on the wall and ground Wear goggles and protective gloves when drilling During drilling the equipment shall be covered to prevent debris from falling into the equipment After drilling the debris shall be cleaned and cl...

Page 15: ...n of the battery lock the M6 40 screw at the top of the support fix the battery and place the battery to slide installation is complete 30cm 30cm 30cm 30cm 4 1 Cable connection 4 Electrical connection A B Anderson connector is used on the DC input side of wall mounted battery series The specific connections are as follows 12 ...

Page 16: ...S485 NC TX RX GND NC NC Explanation RS232 communication BMS can communicate with the upper computer through RS232 interface so that it can monitor various information of the battery through the upper computer including battery voltage current temperature status and battery production information RS485 can communication can communication used for inverter communication RS485 communication With dual...

Page 17: ... L PV combiner box PV INVERTER BATTERY LOAD POWER GRID GND DC Breaker AC Breaker AC Breaker AC Breaker 4 3 System connection diagram Cable color Description Cable color Description DC positive wire DC negative wire Ground wire Live Wire Naught wire Communication line 4 4 battery connection 4 4 1 Single battery connection PV PV PV N GND L BAT BAT RS485 OR CAN AC_OUT AC_IN BAT N GND L INVERTER wirel...

Page 18: ...unication Line RS485 CAN communication Parallel Communication line Line B inverter to combiner box Line C Power line combiner box parallel Explanation The maximum number of batteries can only be connected in parallel is 15pcs After parallel connection the address of ads needs to be assigned as shown below Address 2 3 4 5 6 7 8 9 10 11 12 13 1 0 14 15 Dial switch Remark 1 2 3 4 OFF OFF OFF OFF ON O...

Page 19: ...tion Cable color Description Cable color Description DC positive wire DC negative wire RJ45 Communication Line RS485 CAN communication Parallel Communication line RJ11 Communication Line When the maximum continuous output power of the inverter is greater than 6kW the connection mode is as follows PV PV PV N GND L BAT BAT RS485 OR CAN AC_OUT AC_IN BAT N GND L INVERTER wireless kit RST ADS DO RS485 ...

Page 20: ...and design technical parameters can not be assembled and used together Notice 5 System tuning 5 1 Check before power on NO 1 2 3 4 5 6 7 8 Inspection items Acceptance criteria The energy storage battery is installed in place Reasonable cable layout Beautiful binding of cable ties Reliable grounding Disconnect switch The cable is connected in place Insulate unused terminals and interfaces The insta...

Page 21: ...3200mV Cell06 3200mV Cell07 3200mV Cell08 3200mV Cell09 3200mV Cell10 3200mV Cell11 3200mV Cell12 3200mV Cell13 3200mV Cell14 3200mV Cell15 3200mV Cell16 3200mV ENTER ESC ENTER ESC DOWN ESC DOWN DOWN ENTER ESC PACKV 48 00V Im 50 00A Temperature Cell Voltage DOWN DOWN DOWN ECS ECS DOWN Cell Capacity ENTER DOWN SOC 100 00 FCC 100 0Ah Rm 80 0Ah CC 1 DOWN ECS NO 1 2 3 4 5 6 PACKV Im T1 T4 PCB_T ENV_T ...

Page 22: ...tatus ECS ESC View product BMS protection times information NO NO Items Description Items Description 1 2 3 4 5 6 7 9 10 11 12 13 14 15 8 SCP O UTP OCP UVP OVP OT OTP OV Over voltage protection Up voltage alarm Up voltage protection Over current alarm Over current protection Short circuit protection BMS Failure Short circuit protection Over Up temperature protection Over current protection Up volt...

Page 23: ...ronment temperature protection High environment temperature protection Short Circuit Protection Discharge over current protection Charge over current protection Fully EUT EOT 6 UVP 7 OVP 4 TUVP 11 12 13 14 Total over voltage protection Cell over discharge protection Cell over voltage protection Total under voltage protection MOS High temperature protection MOS OT Discharge low temperature protecti...

Page 24: ...n description The buzzer function can be enabled or disabled by the upper computer It is disabled by default NO Mode Description 1 2 Fault Protection Beep 0 25S every 1S Beep 0 25S every 2S except over voltage protection Beep 0 25S every 3S except over voltage alarm 3 Alarm Battery is in protection state Battery is in normal state Battery is in alarm Explanation Explanation 5 2 3 RST key descripti...

Page 25: ...The maximum power LED flashes flashes 2 and the overcharge alarm ALM does not flash ON ON ON OFF Flash 3 OFF OFF ON ON ON ON ON OFF OFF OFF OFF If there is no mains power LED as standby Close charge Discharge Normal Alarm Under Discharge Protection Temperature Over current Short circuit Fault Protection OFF Flash 3 Flash 3Flash 3 Indication by SOC ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ...

Page 26: ...LEDS on front panel to show the battery working status HMI light flashing mode is the same as LCD light flashing mode 5 2 5 Sleep and wake up When any of the following conditions is met the system enters the low power consumption mode Single or overall over discharge protection is not released within 30 seconds Press the key 3 6S and release the key The minimum monomer voltage is lower than the sl...

Page 27: ...and enter normal charging If the Automatic wake up fails to charge for 10 consecutive times it will no longer wake up automatically When the system is defined as that the recovery voltage is not reached after 2 days of standby standby time setting value after the end of charging it is forced to resume charging until the end of recharging 5 3 wireless kit Optional The wireless kit is divided into t...

Page 28: ... product module Click Add Device or to add products The Message is after sales service Click the connected battery to view the following information Battery information You can view the relevant information of battery voltage working current and capacity Battery pack information You can view the number information of battery accessories Temperature You can view the temperature information of each ...

Page 29: ...re protection DOTP 15 16 17 19 20 21 COTP PCB Sample NTC Protection Charge MOS protection Discharge MOS protection Charge high temperature protection PCB Protection Sample Protection NTC chg MOS dhg MOS 18 Cells Battery Cells Protection NO NO Items Description Items Description 1 2 3 5 8 9 10 DOC COC TUV UV MOS High temperature alarm Low environment temperature alarm High environment temperature a...

Page 30: ...t only needs to meet the environment Double click the main program icon to run it 6 2 Connect the upper computer Ensure that the BMS board is normally powered on and not in sleep state the crystal head of the communication line is inserted into the communication port of the protection board and the USB end is inserted into the computer Double click to start the upper computer Click the try to conn...

Page 31: ...Y ADDR Intervals Close Serial port you can select the drop down item to select the serial port to communicate Note available when the serial port is not opened Baud rate you can select the drop down item to select the baud rate of communication Note available when the serial port is not opened Pack the drop down item can be selected When FF is selected access the RS232 interface of the host to obt...

Page 32: ...witch control Click to enter the screenshot status and the toolbar will appear after marking out the screenshot area with the mouse Displays the flag icon of the current language country Click to switch languages When the button is red it indicates that the function processing is off and when it is green it indicates that it is on Try to connect First set the baud rate and pack on the upper comput...

Page 33: ...the data has not been saved Clear interface data Click the button CLS to clear the real time data on the interface Record data Check Data save to database to start recording data When there is data recording the number of saved data will appear on the right Export data Click the Export button to export the recorded real time data You can also export on the export data page 6 3 3 Store information ...

Page 34: ...face to local Delete record delete the storage record of BMS board when reading the prompt no more data indicates that the reading has been completed 6 3 4 Parameter setting Interface Click the main interface tab Parameter Setting to enter the interface Function Read parameters read all parameters in the interface Explanation 31 ...

Page 35: ...written into the BMS If you need to write please execute the write operation 6 3 5 System settings Interface Click the main interface tab System Config to enter the interface function Just follow the interface prompts Some function operations require administrator privileges 6 3 6 Export data After checking record data on the parallel monitoring page the recorded data can be exported on this page ...

Page 36: ...dependently but only needs to meet the environment Double click the main program icon to run it Connect the computer to the battery via the USB RS485 communication cable Setting for DID Click to open the Inverter software on the PC Select the right serial port Click the Read button to read the current inverter code Click the Write button the inverter code that you need Click the Read button to rea...

Page 37: ...that no tools or other parts are missing in the equipment 8 Battery storage requirements When the battery is stored it shall be placed correctly according to the identification of the packing box and shall not be placed upside down or on the side When the battery packing box is stacked it shall meet the stacking requirements on the outer package The battery shall be handled with care and it is str...

Page 38: ...hall leave a certain time for the company to deal with the faults 10 Exemption from liability The company has the right not to conduct quality assurance under the following circumstances Beyond the free warranty period Incorrect installation modification or use Operate in very harsh environments beyond those described in this manual Machine failure or damage caused by unauthorized installation rep...