Prior to performing any work on an 

Atlas Filtri BIG F PRO

 systems always disconnect the power supply first.

Change the cartridges at least every six months or when a drop in downstream water pressure of 1 bar or 

more is observerd. To change the filter cartridges please adhere to the following procedure: 

Replacement of the cartridge

Follow standards in force regarding waste disposal of used cartridges.

1. Before opening the filter housing turn-off the water mains.

2. Release the pressure from the product by un-screwing the vent-valve of the head. Then screw and 

tighten again the vent-valve.

3. Open the housing unscrewing the bowl using the supplied wrench.

4. Remove the used cartridge.

5. Wipe clean the filter housing with cold water and a soft sponge.

6. Open the new cartridge wrap and discard wrap.

7. Put a new cartridge in the filter housing.

8. Change the O-ring in the top of the filter housing. Check if it is properly located, lubricated and free of any 

damage. Tighten the housing bowl to housing’s head using a proper wrench. Do not over-tighten.

9. Turn-on the water mains, paying attention to completely remove the air left inside the housing using the 

vent valves.

10. Slowly turn-on a water supply (tap) downstream of the 

BIG F PRO

.

11. Open the vent-valve of the head, wait for air purge from the vent-valve, then screw and tighten the 

vent-valve.

 

REMARK:

 let the water flow for at least 5 minutes before use.

Warning

at re-start after every maintenance operation and/or refill change, when the filter’s bowl is unscrewed from 

head, change the o-ring with a new one and carefully lubricate before tightening the bowl to the head. 

Make sure that there are no water leaks from the product and especially control the tightening between the 

housing head and the housing bowl. Continue checking that the tightening is good and there is no water 

leakage for 48 hours following the installation and start-up. In case of leakage, open the housing, remove 

the o-ring from the bowl, place a new o-ring and apply lubricant, then re-tighten the bowl to head and repeat 

the leakage check as above.

Ask your vendor for original o-rings, lubricant and other spare parts.

Use the following step for a full disinfection of the Home and Facility lines before a new installation, 

after service or shut down of the unit.

- Plug In the Unit and remove any “dead ends” in the lines to avoid bacteria harbour.

- Unscrew the sumps and remove the cartridges. Fill the first sump with 1 cup of Bleach ( 5.25% 

Chlorine) and replace the sump.

- Slowly turn on the water supply and run the water for each faucet, toilet, shower heads etc, until 

bleach can be smelled and close it. Wait 30 minutes to let the Chlorine disinfects the utilities.

- Turn off the water inlet and replace the cartridges in the unit. Turn on again and flush every faucet, 

shower heads etc until chlorine smell can no longer been detected.

System disinfection

Summary of Contents for BIG F PRO

Page 1: ...INSTALLATION USE AND MAINTENANCE MANUAL ...

Page 2: ...ITIAL INSTALLATION PROCEDURE LAMP BALLAST OPERATION BALLAST DISPLAY INFORMATION MAINTENANCE CARTRIDGE REPLACEMENT PROCEDURE SYSTEM DISINFECTION LAMP REPLACEMENT PROCEDURE QUARTZSLEEVEMAINTENANCE REPLACEMENTPROCEDURE UV SYSTEM CHARACTERISTICS DECLARATION OF CONFORMITY Pag 3 Pag 3 Pag 4 Pag 4 Pag 4 Pag 4 Pag 5 Pag 8 Pag 8 Pag 10 Pag 10 Pag 10 Pag 12 Pag 12 Pag 13 Pag 15 ...

Page 3: ...ulsory not to connect the appliance to the socket without having first fitted the UV lamp in its housing Caution Atlas Filtri BIG F PRO are designed to reduce turbidity and to kill harmful bacteria and viruses in water supplies Do not use with chemically unsafe water water that does not comply with the legal limits in force in you country or with water of unknown quality It is compulsory to perfor...

Page 4: ... L h 95 lpm INFORMATION ON THE DISPOSAL OF THE SYSTEM Applicable disposal methods may be different in countries outside of the European Union Ask your retailer or local authority about the requirements that apply in your country We remind that according to what is fixed by D L 25 July 2005 151 Accomplishment of directives 2002 CE 2002 96 CE and 2003 108 CE concerning the reduction of the use of da...

Page 5: ...ntact inside their respective packaging 3 Locate a suitable position for the BIG F PRO system remembering to allow 120mm under the housings and at least a chamber length space above the unit for removal of the lamp and sleeve A power outlet with residual current protection is required You can choose the direction of the water flow through the unit depending on whether you have water inlet from the...

Page 6: ...ghtly 11 Connect the flexible hose to the brass nipple and to the inlet of the UV chamber using the supplied gaskets 12 ASSEMBLY OPERATIONS A Open the cover Remove the lamp connector from the top nut disconnecting the ground wire and unscrew the black sleeve bolt warning pay attention to the blue gasket inside B Insert the quartz sleeve carefully centring the seat at the bottom plate of the UV cha...

Page 7: ...7 2a lock unlock 1 2 ground wire seat tighten the ground wire A B C D E F G H ...

Page 8: ...0 days In such case replace the UV lamp and reset the working days count down To reset the working days count down replace the lamp and press and hold for less than 5 seconds the button The value of the days meter will start to flash Within 5 sec press the button again to confirm the days meter reset ATTENTION Do not replace the lamp with power connected to the unit Press and hold for more than 5 ...

Page 9: ...nt down Allarm Buzzer AL2 OFF alternately on display Fix AL2 alarm disconnect the power from the unit and then turn back on Keep pressed for less than 5sec The value of the days meter will start to flash Within 5 sec press again the button to confirm the days meter reset N B if within 5 sec it is not confirmed the days meter comes back to the current counting value 113 AL2 AL2 OFF 113 Remaining li...

Page 10: ...e of 2 weeks or more it may be necessary to replace the cartridges Only original replacement parts from the supplier must be used The following are the recommended service intervals for replacement parts Cartridge Replacement Procedure DAYS COUNTDOWN Alarms AL1 lamp exhaust AL2 lamp OFF DISPLAY OFF replace fuse tc max 70 C after flashing press again to confirm countdown reset Total Days 1 sec Rese...

Page 11: ...e vent valve REMARK let the water flow for at least 5 minutes before use Warning at re start after every maintenance operation and or refill change when the filter s bowl is unscrewed from head change the o ring with a new one and carefully lubricate before tightening the bowl to the head Make sure that there are no water leaks from the product and especially control the tightening between the hou...

Page 12: ...r to maintain disinfection performances 1 Disconnect the power supply and turn off the water 2 Unlock and open the metallic cover 3 Release the water pressure using the filter housing valves on top of the housing head 4 Remove the lamp as for the lamp replacement procedure ATTENTION Wait until the quartz sleeve has cooled down 5 Unscrew the sleeve bolt and extract the quartz sleeve with care 6 Cle...

Page 13: ... class IP 54 Shape Z Flow direction From bottom to top UV LAMP Number 1 Lifespan 9000 hr Lamp power 56 W Type LPHO CONTROL PANEL Material Thermoplastic Dimension 218x113x60 mm Protection class IP 54 Ambient temperature range 4 45 C Power supply 110 240 V 50 60 Hz Lamp cable length 0 6 m Power supply cable 2 m Feed plug AUS Type L Monitor display Digital Days meter Yes for total system life Resetta...

Page 14: ...tection class IP 54 Shape Z Flow direction From bottom to top UV LAMP Number 1 Lifespan 9000 hr Lamp power 67 W Type LPHO CONTROL PANEL Material Thermoplastic Dimension 218x113x60 mm Protection class IP 54 Ambient temperature range 4 45 C Power supply 110 240 V 50 60 Hz Lamp cable length 0 6 m Power supply cable 2 m Feed plug AUS Type L Monitor display Digital Days meter Yes for total system life ...

Page 15: ...ty of machinery electrical equipment of machinery IEC EN 55022 norms characteristics of radio interference D Lgs 31 2001 Implementation of Directive 2015 1787 UE on the quality of water intended for human consumption 2014 68 UE art 4 comm 3 PED The validity of CE marking is subordinated to the equipment integrity Any modification if not authorized will cancel the use of the CE marking This will oc...

Page 16: ...Headquarter via Pierobon 32 Production site via del Santo 227 35010 LIMENA Padova ITALY Tel 39 049 769055 Fax 39 049 769994 www atlasfiltri com ...

Reviews: