REV. 01 2012
32 / 35
CHAPTER 9
–
TROUBLE-SHOOTING
T
ROUBLE
:
P
OSSIBLE
C
AUSE
:
S
OLUTION
:
No display when
switching on
1.
There is no power.
2.
The faulty power plug.
3.
The electrical wires are
disconnected.
4.
Wrong power voltage.
5.
Fuses are blown.
1.
Check power on.
2.
Replace.
3.
Reconnect.
4.
Check for correct voltage.
5.
Replace.
The dimension
measured is not correct.
1.
The gauge is not positioned
correctly when measuring.
2.
The gauge is not calibrated.
1.
Position the gauge correctly.
2.
Calibrate the gauge.
The measurement
gauge cannot function
properly.
1.
The gauge fails to return onto its
orginal position automatically
when the machine is switched on.
2.
The gauge is not calibrated
1.
Reset the gauge.
Switch off and switch on the
machine again.
2.
Calibrate the gauge.
The machine does not
spin when the wheel
guard is closing.
1.
The function
“
start by lowering
guard”
is not enabled.
2.
The wheel guard is not closed
completely.
3.
The electric wire for the micro
switch is disconnected.
4.
The micro switch is not adjusted
properly or faulty.
1.
Enable the function.
2.
Close the guard completely.
3.
Reconnect.
4.
Check for correct adjustment
or replace it if necessary.
Inconsistent unbalance
reading
1.
The machine is shocked.
2.
The machine is not rested solidly.
3.
The wheel is not tightened.
4.
Wrong dimension entry.
5.
The machine is not calibrated.
1.
Do not shock the machine
and restart a spin.
2.
Sit the machine solidly.
3.
Tighten the wheel.
4.
Entry the correcgt data.
5.
Calculate the machine.
Summary of Contents for WB55