![Atlas Copco QAS 500 Volvo S2A APP Instruction Manual Download Page 26](http://html1.mh-extra.com/html/atlas-copco/qas-500-volvo-s2a-app/qas-500-volvo-s2a-app_instruction-manual_3001967026.webp)
- 26 -
Control and indicator panel
Qc2002™
General description Qc2002™ control
panel
A1 ....... Qc2002™ display
F10...... Fuse
The fuse activates when the current from the
battery to the engine control circuit exceeds
its setting. The fuse can be reset by pushing
the button.
H0 ....... Panel light
S2 .......Emergency stop button
Push the button to stop the generator in case
of an emergency. When the button is
pressed, it must be unlocked, before the
generator can be restarted. The emergency
stop button can be secured in the locked
position with the key, to avoid unauthorized
use.
S20 .....ON/OFF switch
Position O: No voltage is applied to the
Qc2002™ module, the generator will not
start.
Position I: Voltage is applied to the
Qc2002™ module, it is possible to start up
the generator.
X25 .....Terminal strip
Qc2002™ Module
The Qc2002™ module is located inside the control
panel. This control module will carry out all
necessary tasks to control and protect a generator,
regardless of the use of the generator.
This means that the Qc2002™ module can be used for
several applications.
H0
A1
F10
S20
S2
X25
X2
X4
X5
X3
Q1
Q2
Q3
Q4
Q5
Q6
N13
X6
L1L2
OFF
L1-N
L2L3
L2-N
L3L1
LL
LN
L3-N
G
Summary of Contents for QAS 500 Volvo S2A APP
Page 1: ...QAS 500 Volvo S2A APP Instruction Manual for AC Generators English...
Page 2: ......
Page 99: ...99 Circuit diagrams...
Page 112: ......
Page 113: ......
Page 114: ...Printed in Belgium 05 2009 2954 3870 00 www atlascopco com...