- 71 -
10
Technical specifications of the light tower
10.1 Technical specifications of the engine/alternator/unit
50 Hz (230V - 1ph)
Reference conditions 1)
Rated frequency
50 Hz
Rated speed
1500 rpm
Generator service duty
PRP
Absolute air inlet pressure
1 bar(a)
Relative air humidity
30%
Air inlet temperature
25°C
Limitations 2)
Maximum ambient temperature
50°C
Altitude capability
3500 m
Maximum relative air humidity
85%
Minimum starting temperature
-5°C
Minimum starting temperature, with coldstart equipment (optional - to be developed)
-25°C
Performance data 2) 3) 4) 5)
Rated active power (PRP) 1 ph
4.9 kW
Rated power factor (lagging) 1ph
1 cos
φ
Rated apparent power (PRP) 1ph
4.9 kVA
Rated voltage 1ph line to line voltage
230 V
Rated current 1ph
21.3 A
Performance class (acc. ISO 8528-5:1993)
G2
Single step load acceptance (0-PRP)
100%
4.9 kW
Frequency droop (lower than % /isochronous)
isochronous
Fuel consumption at no load (0%)
0.86 kg/h
Fuel consumption at 50% load
1.11 kg/h
Fuel consumption at 75% load
1.30 kg/h
Fuel consumption at full load (100%)
1.88 kg/h
Specific fuel consumption
0.324 kg/kWh
Fuel autonomy at full load (100%) with standard tank
55 h
Max. oil consumption at full load
0.02 l/h
00_00_HiLight H4_EN.book Page 71 Monday, April 18, 2016 2:10 PM
Summary of Contents for HiLight H4 Kd ESF
Page 2: ...00_00_HiLight H4_EN book Page 2 Monday April 18 2016 2 10 PM ...
Page 81: ... 81 Circuit diagrams 00_00_HiLight H4_EN book Page 81 Monday April 18 2016 2 10 PM ...
Page 85: ... 85 00_00_HiLight H4_EN book Page 85 Monday April 18 2016 2 10 PM ...
Page 90: ... 90 00_00_HiLight H4_EN book Page 90 Monday April 18 2016 2 10 PM ...
Page 93: ...00_00_HiLight H4_EN book Page 93 Monday April 18 2016 2 10 PM ...
Page 94: ......