background image

 
                               

 

 

 

Page 

 

of 

 

 

 

 

 

 

 

 

 

 

 

 

 

FXLD618C2I LED FIXTURE 

 

Version 0.1  

 

 

 

 

 

 

 

 

 

OWNERS MANUAL   

 

 

 

 

 

 

 

 

      

 06/20/2013 

www.lightronics.com 

Lightronics 

Inc. 

        509 

Central 

Drive 

 

Virginia 

Beach, 

Va 

 

234354 

        

 

 

757 

486 

3588

 

FEATURES AND SPECIFICATIONS 

 

LEDS: 18,  6W each (Warm White, Cool White- 2 in 1) 
Beam angle:  25 º 
Control system: DMX-512 + Stand Alone Modes 
DMX channels:  1/2/3/4/5  
DMX connectors:  3 pin XLR 
Voltage: 120 VAC 50/60Hz 
Max power consumption: 120 Watts 
Refresh Rate:  > 400Hz 
Color Temp.:  3200K - 7000K 
Cooling:  Internal Fan 
Body material: Die Cast Aluminum 
Body color: Black 
Size: 9.9"L x 9.9"W x 9.1"H (without brackets) 
Weight: 10 lbs  (4.5kg) 

 

DESCRIPTION 

 

The FXLD618C2I is a warm white, cool white LED 
lighting fixture.  It is suitable for stage, disco, night 
club, and other artistic applications.  It has several 
stand alone control modes and can operate via a DMX-
512 external signal. 

 

A double yoke enables the fixture to be operated in 
several positions. 

 

INSTALLATION 

 

LOCATION 

 

The FXLD618C2I is rated IP20 and is intended for 

INDOOR USE ONLY.

 

 

Locate the unit in a well ventilated area away from 
moisture and heat.  Keep the vent holes clear.  Holes 
are provided on the  yokes to install a lighting bar pipe 
clamp. Use a safety cable when hanging the fixture.  

 

POWER CONNECTIONS 

 

 
 
 
 

 

The FXLD618C2I has a power cable for connection to 
a 120 VAC, 15 Amp, 60Hz, service. 

 

THE SAFETY GROUND TERMINAL ON THE POWER 
CABLE MUST BE USED. 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

DMX CONNECTIONS 

 

A system using DMX control should be connected as a 
chain of devices.  In other words the control signal 
cable should proceed from the controller to the first 
receiving device and then to others in a continuous 
"daisy chain" fashion. 

 

The fixture has a DMX IN and a DMX OUT connector 
to be used to connect the chain. The control cable 
should NOT be split into a multiple run star 
arrangement with a cable running from the controller 
directly to each receiving device pack. 

 

DMX CONNECTOR PIN ASSIGNMENTS 

 

There are two different connectors which can be used 
for DMX control. They are both XLR type connectors. 
Some units use 3 pin connectors. Others use 5 pin 
connectors. The FXLD618C2I receives a DMX signal 
on the 3 pin MALE connector on one side of the unit.  
The 3 pin FEMALE connector is used to connect the 
next DMX device on the control chain. 

 

If your console uses a 5 pin connector you can make up 
an adapter cable to accommodate this. The following 
table shows the pin assignments for BOTH the 3 pin 
and 5 pin connectors. 

CAUTION    

RISK OF ELECTRIC SHOCK 

Summary of Contents for FXLD618C2I

Page 1: ...to install a lighting bar pipe clamp Use a safety cable when hanging the fixture POWER CONNECTIONS The FXLD618C2I has a power cable for connection to a 120 VAC 15 Amp 60Hz service THE SAFETY GROUND TERMINAL ON THE POWER CABLE MUST BE USED DMX CONNECTIONS A system using DMX control should be connected as a chain of devices In other words the control signal cable should proceed from the controller t...

Page 2: ... address of the unit with the UP and DOWN buttons For DMX operation the FXLD618C2I fixture can be configured as a 1 channel 2 channel 3 channel 4 channel or 5 channel unit Set the CH menu to P001 1 channel A001 2 channel F001 3 channel D001 4 channel or H001 5 channel Detailed information on DMX channel operation is given in the tables DMX VALUES AND FUNCTIONS MANUAL OPERATION For manual operation...

Page 3: ...nt can be used sparingly if needed Ensure that the unit is completely dry before re use REPAIR The fixture contains a 2 Amp fast acting 5mm x 20mm externally accessible fuse Replace the fuse ONLY with the same size and type The FXLD618C2I does not contain any other user serviceable parts Internal service on the unit by other than Lightronics authorized agents will void the warranty If service is r...

Page 4: ...Page 4 of 6 FXLD618C2I LED FIXTURE Version 0 1 OWNERS MANUAL 06 20 2013 www lightronics com Lightronics Inc 509 Central Drive Virginia Beach Va 234354 757 486 3588 MENU NAVIGATION ...

Page 5: ... MODE H CHANNEL NO FUNCTION 1 0 255 Master Dimmer CHANNEL NO FUNCTION 1 0 255 Warm White Level 2 0 255 Cool White Level CHANNEL NO FUNCTION 1 Master Dimmer 2 0 255 Warm White Level 3 0 255 Cool White Level CHANNEL NO FUNCTION 1 Master Dimmer 2 Strobe Control 3 0 255 Warm White Level 4 0 255 Cool White Level CHANNEL NO FUNCTION 1 Master Dimmer 2 Strobe Control 3 0 255 Warm White Level 4 0 255 Cool ...

Page 6: ...erves the right to make any changes modifications or updates as deemed appropriate by Lightronics to products returned for service Such changes may be made without prior notification to the user and without incurring any responsibility or liability for modifications or changes to equipment previously supplied Lightronics is not responsible for supplying new equipment in accordance with any earlier...

Reviews: