Resulting service actions to be carried out
Service actions according to At
Service plan A and B
4000 running hours
Service plan A, B and C
8000 running hours
Service plan A and B
12000 running hours
Service plan A, B and C
16000 running hours
Service plan A, B, C and D
24000 running hours
...
...
Procedure
Starting from the Main screen (see
):
• Press the ‘Menu’ key (F1).
• Press the arrow down key (1) until ‘Modify Params’ is followed by a horizontal arrow.
• Activate the menu by pressing the tabulator key (2).
• Press the arrow down key (1) until ‘Service Plan’ is followed by a horizontal arrow.
• Press the tabulator key (2): a screen similar to the one below will appear:
‘Service Timer’
‘Running hours’
‘hrs’
2130
‘Menu’
F1
F2
F3
• The screen shows the actual running hours.
• Press the tabulator key (2): a screen similar to the one below will appear:
‘Service Timer’
‘Level A’
‘hrs’
4000
‘Menu’
‘Mod.’
F1
F2
F3
• The screen indicates that the level for Service plan A is set at 4000 running hours.
• Press the ‘Mod.’ key (F2). The key ‘Lim.’ (F2) can be used to find out the limitations for the parameter.
Use the arrow up and arrow down keys to modify the interval.
• Press the ‘Prog’ key (F1) to program the new setting or the ‘Canc’ key (F3) to cancel the modification
operation.
• The procedure to modify the Service plans B, C and D is similar.
Instruction book
44
2920 1634 04