• If a shut-down warning exists, LED (1) is lit. The Main screen will change into a screen similar to the one
below:
‘Compr. Outlet’
bar
7.0
‘*Shd’
‘Warn*’
‘Menu**’
F1
F2
F3
• The indicators (**) are flashing.
• Press the key ‘Menu’ (F1) and the tabulator key (2) to select the ‘Status data’ menu; the option ‘Protection’
is flashing.
• Scroll to this option and select it by pressing the tabulator key (2). A screen similar to the one below
appears:
‘Element Outlet’
˚C
‘Shdw’
‘Max’
116
‘Menu**’
110
F1
F2
F3
• The screen indicates that the temperature at the outlet of the compressor element exceeds the programmed
shut-down warning level.
• If necessary, stop the compressor by means of stop button (4) and wait until it has stopped.
• Switch off the voltage, inspect and remedy.
• The warning message will disappear automatically as soon as the warning condition disappears.
A service warning exists
• LED (1) is lit. The Main screen will change into a screen similar to the one below:
‘Compr. Outlet’
bar
7.0
‘*Serv.Requir.*’
‘Menu**’
F1
F2
F3
• The indicators (**) are flashing and the service warning message appears.
• Press the key ‘Menu’ (F1) and the tabulator key (2) to select the ‘Status data’ menu: the option ‘Service’
is flashing.
• Scroll to this option and select it by pressing the tabulator key (2); following options may flash:
• ‘Inputs’: if the programmed service level of a component is exceeded (e.g. the maximum pressure drop
of the oil separator).
• ‘Plans’: if a service plan interval is exceeded.
• Stop the compressor and switch off the voltage.
• If the service message was referring to ‘Inputs’ (oil separator): replace the separator, switch on the voltage,
scroll in the ‘Status data’ menu to ‘Inputs’ and press the ‘Rset’ key to reset the service message.
• If the service message was referring to ‘Plans’: carry out the service actions related to the indicated plans.
Reset the timers of the related plans. Contact your Atlas Copco Customer Centre. See section