• The screen also shows a horizontal arrow indicating that the shut-down warning value can be modified
(the procedure is similar to the description above).
• The procedure to modify other items is similar. For some settings, a delay can be programmed.
The regulator will not accept new values beyond the limits. Press the key ‘Lim.’ to check the
limits for the parameter. Consult Programmable settings for the most important settings.
3.19 Modifying service plans
Control panel
Function
To modify the hour intervals for the service levels.
Service plans
The service actions to be carried out are grouped in plans called Service level A, B, C or D. When reaching
an interval, a message will appear on the screen indicating which Service plans are to be carried out.
Always consult your Atlas Copco Customer Centre if any timer should be changed. The
intervals must not exceed the intervals below and must coincide logically.
Programmed service plan intervals
Service plans
Intervals
Service plan A
Each 4000 running hours
Service plan B
Each 4000 running hours
Service plan C
Each 8000 running hours
Service plan D
Each 24000 running hours
The regulator will not accept new values beyond the limits. Press the key ‘Lim.’ to check the
limits for the parameter. Consult
for the most important settings.
Instruction book
2920 1634 04
43