3.8
Quick look at the actual compressor status
Procedure
Control panel
Starting from the Main screen (see section
), press the arrow down key (3): A
screen similar to the one below appears:
Example of the compressor status screen
‘Auto operation’
‘Local control’
‘Timer active’
‘Main’
‘Help’
‘Xtra’
F1
F2
F3
Line 1 indicates the automatic or manual operation status of the regulator: ‘Auto operation’
means that the regulator automatically adapts the operation of the compressor, i.e. matching the
compressor output to the air consumption.
Line 2 indicates whether the regulator is operating in local control or remote control mode: ‘Local
control’ means that the start/stop buttons on the keyboard are activated. ‘Remote control’ means
that these functions are controlled remotely.
Line 3 indicates whether the timer which generates time-based start and stop commands is
activated or not.
Press the arrow down key (3) to get other data (actual condition of the compressor). See section
.
Instruction book
API161475