![Atlas Copco GA 11 VSD Instruction Book Download Page 23](http://html.mh-extra.com/html/atlas-copco/ga-11-vsd/ga-11-vsd_instruction-book_3001653023.webp)
3.3
Scroll keys
Control panel
The keys (1) allow the operator to scroll through the display.
As long as a downwards pointing arrow is shown at the far right position of the display, the scroll
key with the same symbol can be used to see the next item.
As long as an upwards pointing arrow is shown at the far right position of the display, the scroll
key with the same symbol can be used to see the previous item.
3.4
Emergency stop button
Control panel
In the event of an emergency, press button (S3) to stop the compressor immediately.
Before starting any maintenance or repairs, wait until the compressor has stopped and
open the isolating switch (customer's installation) to switch off the voltage to the
compressor.
Close the air outlet valve and open the manual condensate drain valves to depressurise the
air system.
Apply all relevant
3.5
Control programs
Description
In order to facilitate programming and controlling, menu-driven control programs have been
implemented in the regulator.
Instruction book
API161475
21