Instruction book
2920 1521 00
31
Period
Running
hours
Service
Plan
See
section
See
notes
below
table
Operation
Daily
-- -- 3.4
--
Drain
condensate
"
--
--
--
--
On SF Full-Feature, check dewpoint
Monthly
250
--
5.1
1
Inspect air filter
3-monthly
500
-- -- --
Check
pressure
drop
over Atlas Copco filters
(optional)
6-monthly
-- -- 5.4
--
Operate
safety
valve
"
-- -- -- --
Clean
compressor
"
--
--
--
--
On SF Full-Feature, brush or blow off the finned
surface of the condenser
"
--
--
--
--
On SF Full-Feature, clean condensate trap
internally
Yearly
-- -- 5.4
--
Test
safety
valve
"
-- -- -- --
Have
electrical
components/shut-down
switch
tested
"
2500
I
5.2
--
Check tension/condition of V-belt(s)
"
5000
A
5.1
--
Replace air filter
"
5000
A
--
2
Have ball valve mechanism of condensate trap
inspected
"
5000
A
5.2 -- Replace
V-belt(s)
2-yearly
5000
B
--
2
Have orbiting scroll bearing greased
"
10000
B
--
2
Clean compressor element fan and duct. Clean
compressor element fins, have seals replaced
"
10000
B
--
2
Have pin crank bearings greased
Notes:
1.
Check more frequently if operating in a dusty atmosphere. Check for cleanness and damage.
Replace a dirty or damaged filter by a new one.
2.
Consult Atlas Copco.