8. CAUTION 

 

Working Environment 
1)

 

Welding should be carried out in dry environment with humidity of 90% or less. 

2)

 

The temperature of the working environment should be between -10

 and 40

3)

 

Avoid welding in the open air unless sheltered from sunlight and rain. Keep it dry at all times and do not place it 
on wet ground or in puddles. 

4)

 

Avoid welding in dusty area or environment with corrosive chemical gas. 

5)

 

Gas shielded arc welding should be operated in environment without strong airflow. 
 

Safety Tips 
Over-current/over-voltage/over-heating protection circuit is installed in this machine. When the network voltage, 
output current or inner temperature exceeds the set standard, the machine will stop automatically. However, excessive 
use (e.g. too high voltage) of machine will lead to welder damage. Therefore, please note: 
1)

 

Ventilation 
This welder can create powerful welding current that has strict cooling requirements that cannot be met with 
natural ventilation. Therefore the internal fan is very important in enabling the machine to work steadily with 
effective cooling. The operator should make sure that the louvers be uncovered and unblocked. The minimum 
distance between the machine and nearby objects should be 30cm. Good ventilation is of critical importance to 
the normal performance and lifespan of the machine. 

2)

 

Welding operation is forbidden while the machine is overload. Remember to observe the max load current at any 
moment (refer to the corresponding duty cycle). Make sure that the welding current should not exceed the max 
load current. Overload could obviously shorten the machine's lifespan, or even damage the machine. 

3)

 

Over-voltage is forbidden. 
Regarding the power supply voltage range of the machine, please refer to “Technical Parameters” table. This 
machine is of automatic voltage compensation, which enables the maintaining of the voltage range within the 
given range. In case that the input voltage exceeds the stipulated value, it would possibly damage the 
components of the machine. 

4)

 

An earth terminal is available for the machine. Connect it with an earth cable (section≥6mm

2

) to avoid the static 

and electric shock.  

5)

 

A sudden halt may occur with the red LED on the front panel on while the machine is of over-load status. Under 
this circumstance, it is unnecessary to restart the machine. Keep the built-in fan working to lower the temperature 
inside the machine. Welding can be continued after the inner temperature falls into the standard range and the 
red LED is off. 

 
 
 
 
 
 
 
 
 
 
 

9.  MAINTENANCE  

The following operation requires sufficient professional knowledge on electric aspect and comprehensive  safety 
knowledge.  Operators  should  be  holders  of  valid  qualification  certificates  which  can  prove  th eir  skills  and 
knowledge.  Make  sure  the  input  cable  of  the  machine  is  disconnected  from  the  electricity  utility  before 
uncovering the welding machine. 

1.

 

Check periodically whether inner circuit connection is in good condition (esp. plugs). Tighten the loose connection. 
If there is oxidization, remove it with sandpaper and then reconnect. 

2.

 

Keep  hands,  hair  and  tools  away  from  the  moving  parts  such  as  the  fan  to  avoid  personal  injury  or  machine 
damage. 

3.

 

Clean  the  dust  periodically  with  dry  and  clean  compressed  air.  If  welding  environment  with  heavy  smoke  and 
pollution, the machine should be cleaned daily. The pressure of compressed air should be at a proper level in 
order to avoid the small parts inside the machine being damaged. 

4.

 

Avoid rain, water and vapor infiltrating the machine. If there is, dry it and check the insulation of the equipment 
(including that between the connections and that between the connection and the enclosure). Only when there are 
no abnormal phenomena anymore, can the machine be used. 

5.

 

Check  periodically  whether  the  insulation  cover  of  all  cables  is  in  good  condition.  If  there  is  any  dilapidation, 
rewrap it or replace it.  

6.

 

Put the machine into the original packing in dry location if it is not to be used for a long time. 

Summary of Contents for Zeneo Compact 200

Page 1: ...LANTIC 180 Ref 22290202AC ATLANTIC 200 E ESTE EQUIPO DEBE SER UTILIZADO POR PROFESIONALES EN BENEFICIO DE SU TRABAJO LEA ATENTAMENTE ESTE MANUAL GB THIS EQUIPMENT MUST BE USED BY PROFESSIONALS TO HELP...

Page 2: ...ag 13 3 FUNCTION OVERVIEW Pag 14 4 PERFORMANCE CHARACTERISTICS Pag 14 5 TECHNICAL PARAMETERS Pag 14 6 OPERATION CONTROL AND DESCRIPTION Pag 15 7 INSTALLATION DEBUGGING AND OPERATION Pag 16 8 CAUTION P...

Page 3: ...desprotegida ni con los guantes o la ropa mojada Aseg rese de que se encuentra aislado de la tierra y de la pieza Confirme la seguridad de su puesto de trabajo El humo puede resultar nocivo para la sa...

Page 4: ...os que lleve a cabo una inspecci n con arreglo a los contenidos relacionados Si no llega a identificar la aver a o a solucionar el problema le rogamos que se ponga en contacto con el distribuidor o el...

Page 5: ...avanzado La tecnolog a de control avanzado es apropiada para diferentes aplicaciones de soldadura y mejora considerablemente el rendimiento de sta Puede ser muy utilizada en la soldadura con electrodo...

Page 6: ...uptor general ON OFF 10 Se al de advertencia 11 Entrada de corriente cable de entrada de corriente 12 Ventilador de refrigeraci n 7 INSTALACI N PUESTA A PUNTO Y FUNCIONAMIENTO Nota Le rogamos que inst...

Page 7: ...1 Una vez instalada la m quina con arreglo al procedimiento anterior y encendido el interruptor general de corriente la m quina est en funcionamiento con el LED de corriente encendido y con el ventil...

Page 8: ...ebe asegurarse de que las rejillas no est n obstruidas ni bloqueadas La distancia entre la m quina y cualquier objeto de alrededor no debe ser inferior a 30 cm Una buena ventilaci n es primordial para...

Page 9: ...l objeto de evitar lesiones corporales o da os a la m quina 3 Quite peri dicamente el polvo utilizando aire comprimido seco y limpio Si la soldadura se lleva a cabo en un ambiente cargado de humos y c...

Page 10: ...potenci metro 1 El potenci metro de corriente est averiado Sustit yalo 2 Compruebe la existencia de contactos flojos o sueltos dentro de la m quina En caso afirmativo apri telos o vu lvalos a conectar...

Page 11: ...284 Tubo PMOS IRF9Z24N 14 10037146 TOP266KG ESOP 12 15 10037147 LM79L15ACMX SO 8 EMBALAJE TRANSPORTE Y ALMACENAMIENTO 1 Embalaje N Nombre Unidad Cantidad 1 Manual de usuario para la serie ARC Ingl s V...

Page 12: ...or wet clothes Be sure you are insulated from ground and workpiece Confirm the safety of your working position Smoke may be harmful to your health Keep your head away from the smoke to avoid inhalatio...

Page 13: ...operation please inspect according to related contents in this manual If you still cannot understand fully or you still cannot solve the problem please contact the dealer or the service center of GAL...

Page 14: ...Advanced control technology meets various welding applications and greatly improves the welding performance It can be widely used in acid and basic electrode welding Easy arc starting less spatter sta...

Page 15: ...ob To adjust the output current 8 Handle Fig 3 9 Power switch Power ON OFF switch 10 Warning sign 11 Power input power input cable 12 Cooling fan Fig 4 INSTALLATION DEBUGGING AND OPERATION Note Please...

Page 16: ...acid electrode Operation TIG Fig 7 Schematic Diagram of Lift Arc TIG Welding 1 After being installed according to the above method and the power switch being switched on the machine is started with t...

Page 17: ...in the given range In case that the input voltage exceeds the stipulated value it would possibly damage the components of the machine 4 An earth terminal is available for the machine Connect it with a...

Page 18: ...s Replace it 4 Check if any loose contact exists inside the machine If any reconnect Turn on the machine the power LED is on the fan works but no welding output 4 Check if any loose contact exists ins...

Page 19: ...06284 PMOS tube IRF9Z24N 14 10037146 TOP266KG ESOP 12 15 10037147 LM79L15ACMX SO 8 PACKING TRANSPORTATION AND STORAGE A1 Packing No Name Unit Quantity 1 User s manual for ARC series English Volume 1 2...

Page 20: ...la peau non prot g e ou si vous portez des v tements ou des gants mouill s Assurez vous que vous tes bien isol par rapport la terre et la pi ce Confirmez la s curit du poste de travail La fum e peut...

Page 21: ...le fonctionnement de l quipement veuillez proc der une inspection conform ment aux contenus concern s Si vous ne parvenez pas identifier la panne ou r soudre le probl me veuillez contacter le distrib...

Page 22: ...logie de contr le avanc est appropri e pour diff rentes applications de soudage et am liore consid rablement leur rendement Elle peut tre tr s largement utilis e pour le soudage avec des lectrodes de...

Page 23: ...9 Interrupteur g n ral Interrupteur g n ral ON OFF 10 Signal d avertissement 11 Entr e de courant C ble d alimentation de courant 12 Ventilateur de refroidissement Fig 4 7 INSTALLATION R GLAGE ET FONC...

Page 24: ...que de Soudage TIG Lift Arc 1 Une fois la machine install e conform ment la proc dure ant rieure et l interrupteur g n ral de courant allum la machine est en marche avec le LED de courant allum et le...

Page 25: ...es Dans le cas o la tension d entr e d passerait la valeur tablie il est possible qu elle puisse endommager les composants de la machine 4 La machine est dot e d une borne de mise la terre Connectez l...

Page 26: ...ut pas tre contr l par le potentiom tre 5 Le potentiom tre de courant est en panne Remplacez le 6 V rifiez s il y a des contacts peu serr s ou desserr s l int rieur de la machine Si c est le cas serre...

Page 27: ...ube PMOS IRF9Z24N 14 10037146 TOP266KG ESOP 12 15 10037147 LM79L15ACMX SO 8 EMBALLAGE TRANSPORT ET STOCKAGE A1 Emballage N Nom Unit Quantit 1 Manuel d utilisation pour la gamme ARC Angl s Volume 1 2 C...

Page 28: ...kes to repair it without any additional charge unless the damage caused to the product is the result of accidents improper use negligence inappropriate accessories unauthorized servicing or modificati...

Page 29: ...QUIREMENTS OF THE EEC STANDARD D CLARA QUE LES PRODUITS PR SENT S ET R FERENC S DANS LE MANUEL D INSTRUCTION SONT CONFORMES AUX DIRECTIVES COMMUNAUTAIRES APPLICABLES POUR LE MARQUEE CE PRODUCTO ATLANT...

Page 30: ...encia carga Thermal Resistor 13 10006474 Rel de entrada Electric Relay 14 10029693 IGBT IGBT 15 10037852 T rmico de protecci n Thermal Switch 16 10037135 Transformador de impulsos Drive Transformer 17...

Page 31: ...encia carga Thermal Resistor 13 10006474 Rel de entrada Electric Relay 14 10029693 IGBT IGBT 15 10037852 T rmico de protecci n Thermal Switch 16 10037135 Transformador de impulsos Drive Transformer 17...

Page 32: ...OLDADURA AUTOGENA ELECTRICA Y CONSTRUCCIONES ELECTROMECANICAS CENTRAL Jaime Ferr n 19 nave 30 Apartado de Correos 5058 50080 ZARAGOZA Tel fono 976 47 34 10 Telefax 976 47 24 50 E mail comercial galaga...

Reviews: