Atlantic TWVSC Product Manual Download Page 2

2

Thank you for purchasing the TidalWave Variable Speed Controller (VSC). The TidalWave 
VSC is intended for use with TidalWave TW and TT Series asynchronous pumps. The  
TidalWave VSC allows the user to set both on and off times as well as drop to 25% of the 
total flow, in 10 levels of adjustment, manually via the control panel or by wireless remote. 
To avoid an accident do not use the TidalWave VSC in any way other than as described 
in this manual. Please note the manufacturer cannot be responsible for accidents arising 
because the product was not used as prescribed. After reading this manual keep it as a 
reference in case questions arise during use.

Prior to Operation and Installation

Before the VSC is installed, perform the following checks:
•  Check for any damage to VSC control box and power cable that may have occurred  
    during shipment.
•  Check the model number to make sure it is the product that was ordered and verify the  
    voltage and frequency are correct.

Caution

•  DO NOT operate this product under any conditions other than those for which it is  
    specified. Failure to observe these precautions can lead to electrical shock, product  
    failure or other problems.
•  Follow all aspects of electrical codes when installing the TidalWave VSC.
•  Power supply must be within 110-120 volt range and 60 Hz.
•  This product is equipped with overload protection, <150 percent of the full load  
    current rating.
•  Never use an extension cord with this product. The VSC must be plugged directly into  
    an electrical outlet.
•  This product should be installed and/or stored in an area that is protected from weather  
    exposure. It must be mounted off the ground close to the power source. Failure to do  
    so will void the warranty.
•  The TidalWave VSC is intended for use with TidalWave TW and TT-Series  
    asynchronous pumps.

CAUTION: THIS TIDALWAVE VSC IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND 
FAULT CIRCUIT INTERRUPTER.

CAUTION: THIS PRODUCT HAS BEEN EVALUATED FOR USE WITH ASYNCHRONOUS WET  
ROTOR PUMPS ONLY. DO NOT USE WITH MAGNETIC INDUCTION OR DIRECT DRIVE PUMPS.

WARNING: RISK OF ELECTRIC SHOCK - THIS PRODUCT IS SUPPLIED WITH A  
GROUNDING CONDUCTOR AND GROUNDING-TYPE ATTACHMENT PLUG. TO REDUCE 
THE RISK OF ELECTRIC SHOCK, BE CERTAIN THAT IT IS CONNECTED ONLY TO A  
PROPERLY GROUNDED RECEPTACLE PROTECTED BY A GROUND FAULT CIRCUIT  
INTERUPTER (GFCI).

Electrical Safety

•  Electrical wiring should be installed by a qualified electrician in accordance with all  
    applicable safety regulations. Incorrect wiring can cause VSC failure, pump malfunction,  
    electrical shock or fire.
•  All TidalWave pumps and TidalWave VSC should operate on a designated, 110/120  
    volt circuit.
•  TidalWave VSC must be protected by a ground fault circuit interrupter (GFCI).
•  TidalWave VSC must be plugged into a standard, properly grounded, three  
    pronged outlet.

Summary of Contents for TWVSC

Page 1: ...C U S TÜVRheinland TWVSC Product Manual Manuel du Produit Manual del Producto 1 330 274 8317 www ATLANTICWATERGARDENS com P ...

Page 2: ...0 Hz This product is equipped with overload protection 150 percent of the full load current rating Never use an extension cord with this product The VSC must be plugged directly into an electrical outlet This product should be installed and or stored in an area that is protected from weather exposure It must be mounted off the ground close to the power source Failure to do so will void the warrant...

Page 3: ...he slotted pockets allow the VSC to be easily removed from the mounts to access the pump connection for servicing The VSC should be mounted above the ground on a wall or post away from direct sunlight Ensure that the VSC is within reach of a properly grounded GFCI outlet and the electrical cord of the pump that will be used Remove the VSC from the mounting location and remove the cord cover locate...

Page 4: ...mer must be performed via the buttons and display located on the VSC control box After ten seconds of inactivity during any part of the programming sequence the selection will be entered and the VSC will exit the program functions and return to the main clock display SET V A R I A B L E S P E E D C O N T R O L L E R To turn the pump off press the power button The word OFF and a 00 flow level will ...

Page 5: ...power button when the START and STOP times are flashing The time will be replaced with a large OFF indicating the timer is deactivated SET SET Maintenance and Inspection Regular maintenance and inspections are recommended to determine that everything is operating properly If any abnormal conditions are noticed refer to the section on Troubleshooting and take corrective measures immediately Winteri...

Page 6: ...the remote to re sync VSC is out of range Decrease distance Diminished pump flow rate or no intermittent water flow Flow level is set too low Raise the flow level on the VSC Incorrect timer settings Verify timer is set correctly Low water level Stop operation Raise water level Pump requires service maintenance Follow manufacturer recommendations for pump service and maintenance Troubleshooting Gui...

Page 7: ... et un cycle de 60 Hz Ce produit est équipé d une protection contre les surcharges 150 pour cent de la pleine charge courant nominal N utilisez jamais une rallonge avec ce produit Le VSC doit être branché directement dans une prise électrique Ce produit doit être installé et ou stocké dans une zone qui est protégée contre les intempéries Celui ci doit être installé plus haut que le niveau du sol e...

Page 8: ...directe du soleil Assurez vous que le VSC se trouve à proximité d une prise correctement mise à la terre du disjoncteur de fuite de terre et du cordon d alimentation de la pompe qui sera installée Retirez le VSC de l emplacement de montage et retirez la housse du cordon située à l arrière de l appareil Fig 1 Du fait que les fiches électriques des pompes présentent différentes tailles un dispositif...

Page 9: ...ffichage d horloge principal SET V A R I A B L E S P E E D C O N T R O L L E R Pour activer la pompe il suffit d appuyer sur le bouton d alimentation Vous verrez la mention ON marche et le niveau de débit affichés à l écran Utilisez les boutons haut et bas pour réguler le débit Chaque fois que le débit est ajusté le niveau est affiché pendant trois secondes avant de retourner à l affichage princip...

Page 10: ...tra à clignoter Utilisez les boutons haut et bas pour sélectionner l heure Après avoir sélectionné l heure appuyez sur le bouton de réglage et les minutes se mettront à clignoter Utilisez les boutons haut et bas pour sélectionner les minutes SET Une fois satisfait de l heure de DÉBUT programmée appuyez sur le bouton de réglage La mention OFF arrêt en petit format s affichera à gauche de l écran et...

Page 11: ...nce Débit de la pompe réduit ou inexistant intermittent Le réglage du niveau de débit est trop bas Hausser le niveau du débit du VSC Mauvais réglages de la minuterie Vérifier si la minuterie est bien réglée Faible niveau d eau Arrêter le fonctionnement de l appareil hausser le niveau d eau La pompe doit faire l objet d une réparation ou d un entretien Suivre les recommandations du fabricant pour t...

Page 12: ... voltios y 60 Hz Este producto está equipado con protección de sobrecarga 150 por ciento de la corriente nominal a plena carga Nunca utilice un cable de extensión con este producto La VSC debe ser conectada directamente a un tomacorriente Este producto debe ser instalado y o almacenado en un área que está protegida de la intemperie Lo debe montar sin apoyarlo en el suelo cerca de la fuente de alim...

Page 13: ...a en la salida empotrable situada debajo de la cubierta del cable Fig 2 Instale el seguro del cordón si es necesario y vuelva a colocar la cubierta del cable Fig 3 Devuelva la VSC a la ubicación de montaje y conecte el cable de alimentación eléctrica al tomacorriente GFCI 13 La TidalWave VSC debe enchufarse en un tomacorriente estándar de tres clavijas con la debida descarga a tierra Instrucciones...

Page 14: ...RT STOP El reloj y el cronómetro no necesitan ser programados para operar la VSC La programación del reloj y el cronómetro se debe realizar mediante los botones y la pantalla que se encuentran en la caja de control de la VSC Después de diez segundos de inactividad durante cualquier parte de la secuencia de programación se ingresará la selección y la VSC saldrá de las funciones del programa y volve...

Page 15: ...ue indica que se ingresó la programación Para desactivar las funciones del temporizador de INICIO PARADA START STOP repita los pasos de programación y presione el botón de energía cuando las horas de INICIO y PARADA estén parpadeando en la pantalla Se remplazará el tiempo con un grande OFF que indica que el cronómetro está desactivado SET SET Mantenimiento e inspección Se recomienda mantenimiento ...

Page 16: ...o comuníquese con la empresa de energía eléctrica local El cable de alimentación eléctrica no está conectado Conecte el cable de alimentación eléctrica La VSC no re sponde al control remoto Baterías agotadas conexión con batería Remplace las baterías verifique la orientación El remoto no está sincronizado con la VSC Desconecte la VSC durante 10 segundos Vuelva a conectar y presione el botón de ene...

Reviews: