![Atlantic TA 200 Manual Download Page 22](http://html.mh-extra.com/html/atlantic/ta-200/ta-200_manual_3000066022.webp)
22
GB
9) ERRORS/SOLUTIONS
When the appliance displays an error code, contact your installer
Code
Error Description
Code
Error
Code
Error
E0
Unit sensor error
E8
Electrical leakage protection activated
P9
Overvoltage protection on the electrical unit
E2
Communication error between the tank and
the controls
P0
Evaporator sensor temperature too low
LA
Ambient temperature is wrong for the heat
pump.Change to electrical mode or shut off.
E4
Temperature sensor error on the evaporator
connections
P2
Compressor output sensor temperature too
high
E5
Ambient temperature sensor error
P3
Compressor power supply malfunction
E6
Heat pump error
P4
Compressor overvoltage
E7
Compressor circuit opening protection
P8
Electrical circuit opening protection
• When an error is detected, the buzzer sounds every minute, the ALARM indicator blinks, and the error code appears on the screen instead of the temperature
$
. Hold down the
RESET button for 3 seconds to stop the alarm. After the error has been corrected, the error code disappears. To restart, shut off and restore the power.
The alarm can also be triggered in the following situations: Obstruction at the air inlet or outlet, clogged evaporator (dust, etc.), incorrect voltage, etc.
• Call a technician if the buzzer sounds in any of the following situations.
Problem
Cause
Solution
Cold hot water and a dark screen
Incorrect or insuffi cient supply of electricity
Check the electrical supply
The water temperature setting is too low
Increase the desired temperature on the screen
The electronic regulator or temperature indicator is broken
Call your installer
Cold hot water and a working screen
The water setup does not meet requirements, and there
is a mix between the hot water and the cold water supply
Call your installer
No hot water fl ow
Supplied pressure too low
Check that the water pressure > 1.5 bar
Water inlet closed or water shut off
Check the water supply and tap openings