15
GB
Ref.
TWH 200 / TA 200
TWH 250 / TA 250
Capacity
200
250
Working pressure (bar)
8
Testing pressure (bar)
16
Instructions
Auto/manual, error mode, alarm
Normal/maximum (W) compressor power
470 / 600
Refrigerant gas
R134a (850 g / max pressure 30 b)
Motor power (W)
30
Water temperature
65°C (38 à 70°C)
Heat pump operating range
5 to 43°C
Electrical heating operating range
-15 to 5°C
Electrical power (W)
1500
1500
Voltage/Frequency (V/Hz)
230V~ 50Hz
230V~ 50Hz
Max amperage (A)
6.5 A
6.5 A
Total maximum power (W)
1500 W
1500 W
Heat pump heating time (15 to 50°C)
6h30
8h30
available water volume when electrically heated (I)
150
210
Heating time - electrical part (min)
Δ
t= 50°C
5h20
7h20
Indicative COP (room temperature 20°C /
water temperature 51°C)
2,7
2,7
Noise level (dB)
48
48
Air fl ow (m
3
/ h)
350
350
A
P
B
C
D
E
F
G
⍺
weight
200
1565
605
270
880
880
678
2
3/4”
70°
83
250
1868
605
270
1186
1186
678
2
3/4”
70°
94
575
B
C
P
F
G
Ø 567
α
A
E
D