25
CONNECTING THE APPLIANCE
Connection guidelines
-
The appliance must be supplied with 230V 50 Hz.
-
The appliance must be directly connected to the mains downstream
of the omnipolar cut-off device in accordance with installation
guidelines. A 3-wire cable (Brown = Phase, Blue = Neutral, Black =
Pilot wire) is used to connect to the supply circuit through a junction
box.
-
In humid rooms, such as kitchens and bathrooms, the junction box
must be installed at least 25 cm from the ground. The installation
must be equipped with a 30mA residual-current circuit-breaker
protective device.
-
Connection to ground is prohibited. Do not connect the pilot wire
(black) to ground.
-
If the power cable is damaged, it must be replaced by the
manufacturer, their after sales department or by a similarly qualified
person, in order to avoid any danger.
-
If the control or controlled device is protected by a 30mA residual-
current circuit-breaker protective device (e.g. in the bathroom) then
the power supply for the pilot wire on this differential needs to be
protected.
Power
C
750W
343
1000W
1250W
565
1500W
2000W
787
Panel heater cable
Phase=brown
Neutral=blue
PHASE
NEUTRAL
Electricity
grid
Three possible cases
Pilot wire=Black
1st case: only one heater
2nd case: Slave heater
The pilot wire end is insulated
and not further connected
To the appliance with cassette or
programming unit.
Drill points A
Drill points A
Drill points B
C