Manual manoeuvre:
opens all the channels for
¿OOLQJDQGRUGUDLQDJH
AB
8 Maintenance
8.1
'UDLQLQJWKHK\GUDXOLFPRGXOH
- Remove the front panel of the heat pump.
- Set the directional valve to intermediate position.
- Deactivate the non-return valve (
item
¿JXUH
).
- Open the drainage valves (
item
5
).
- Open the manual drains (
item
6
) and the auto drain of
the hydraulic module (
item
7
).
- Open the installation's drain(s).
8.2 Directional
valve
Channel
AB
: Output to the circulator.
Channel
A
open: Return from the DHW tank.
Channel
B
open: Return from the heating circuit.
8.3 ACI
check
Check the polarity.
Check the voltage: As the appliance is powered up, the
voltage value must be positive and be b 0 and
+ 6.5 V in direct current.
9
9DOXHVWREHJLYHQWRWKHXVHU
Explain to the user the operation of the installation
(heating and hot water temperature settings), especially
the ambient sensor functions and the programmes that
are accessible via the user interface.
(PSKDVL]H WKDW XQGHUÀRRU KHDWLQJ KDV FRQVLGHUDEOH
inertia and that consequently the settings need to be
progressive.
Also explain to the user how to check the heating circuit
LV¿OOHG
U = + 0 à + 6,5 V
Contrôle de l'alimentation ACI
Raccordement
Raccordement ACI :
Le
sur la masse du ballon,
Le
sur le connecteur de l'électrode.
-
+
$&,SRZHUVXSSO\FKHFN
Connection
ACI connection:
to the tank mass
to the electrode connector
The
The
Installation and commissioning instructions "1485 - EN"
- 75 -
Heat pump alféa hybrid duo gas