2.15.5 Electrical connections on outdoor unit side
VLQJOHSKDVHPRGHO
Access to the connector terminals
- Remove the front panel.
- Remove the cover (
¿JXUH
).
- Make the connections according to the diagram
(
¿JXUH
).
- Use the cable clamps to avoid any accidental discon-
nection of the conductive wires.
- Use the attachment plate to hold the cables against
the insulating plate. (item
1
to
3
¿JXUH
).
Attach
WKHFDEOHVVRWKDWWKH\DUHQRWLQFRQWDFWZLWKWKH
pipes and the valves
(item
4
).
2.15.6 Electrical connections on outdoor unit side
WKUHHSKDVHPRGHO
Access to the connector terminals
- Remove the front panel. Remove the screws and the
cover of the front panel.
- Make the connections according to the diagram
(
¿JXUH
).
¿JXUH
Access to the terminal block of the outdoor unit
Remove the screws
and push downwards
Remove the front
panel.
Terminal
block
¿JXUH
Access to the terminal block of the outdoor unit
1
INDOOR UNIT
POWER
2 3 L1 L2 L3 N
Terminal
block
Inter-connection
between outdoor unit
and hydraulic module
General electrical
power supply
¿JXUH)LQDOLVLQJRIWKHFRQQHFWLRQRIWKHRXWGRRUXQLW
Cable
clamp
Cables
(power supply and
inter-connection)
front
lower
side
rear
¿JXUH'XFWVIRUWKHFDEOHVDQGUHIULJHUDWLQJFRQQHF
-
tions of the outdoor unit
- Use the cable clamps to avoid any accidental
disconnection of the conductive wires.
- Obstruct the space at the cable inlet in the outdoor unit
with the insulating plate.
Installation and commissioning instructions "1485 - EN"
- 37 -
Heat pump alféa hybrid duo gas