3.3 Starting the gas generator
WRFKHFNWKHFRPEXVWLRQ
To carry out the combustion checks (during a gas
change or during maintenance), the gas generator can
be started independently of the heat pump (
¿JXUH
)
.
"
During each intervention on the electrical
FDELQHWPDNHVXUHWKDWWKHHOHFWULFLW\VXSSO\LV
disconnected.
- Open all the heating circuit valves.
"
:LWK XQGHUÀRRU KHDWLQJ FLUFXLW DQG FLUFXLW
NLWZLWKYDOYH&ORVHWKHPL[HUYDOYHE\KDQG
3.3.1 Heating installation with radiators
1a
- If the directional valve handle is in low position
(DHW position) (
¿JXUH
)
:
-
1b
- Deactivate the DHW function,
- Wait a few moments for the handle to return to high
position.
2
- The directional valve handle is in high position
(heating position):
3
- In the electrical cabinet, disconnect the RVS user
interface layer (connector X50).
4
- Connect the user interface layer to the LMS (X50).
- Initialising the interface takes a few minutes.
- Set the following parameters (Specialist level:
0DLQWHQDQFHVSHFLDORSHUDWLRQ
):
7143
= On
7145
= Enter the value required
100%
: operation at max
0%
: operation at min
"
When the checks are complete:
6HWWKHSDUDPHWHULQWKHLQLWLDOFRQ¿JXUDWLRQ
7143
= Off
5
-
Reconnect the user interface layer to the RVS
(X50). Initialising the interface takes a few minutes.
6
-
Reactivate the DHW function if necessary.
3.3.2 Heating installation with
1
XQGHUÀRRUKHDWLQJFLUFXLW
"
&ORVHWKHXQGHUÀRRUKHDWLQJFLUFXLWPL[HUYDOYH
PDQXDOO\
The energy created during this setting period
must be dissipated over the domestic circuit:
draw off some domestic hot water to lower the tank
temperature enough (< 35 °C).
1a
- The directional valve handle must be in low
position (DHW position) (
¿JXUH
)
: Follow the
procedure in
§ 3.3.1
from N°
3
.
¿JXUH'LUHFWLRQDOYDOYHLQKHDWLQJSRVLWLRQ
¿JXUH
Temporary connection of the user interface to the
JDVUHJXODWLRQERDUG/06
X12
X13
X14
5
X10
X11
X30
X50
X70
X60
Carte régulation
PAC
Interface COM
Ventilateur
X6b
Carte régulation
gaz
X10b
X8a
X50
X15a
X16a
X4a
X11
X7b
X30
Interface COM
(OCI 345)
X12
X13
X14
X75
X10
X11
X30
X50
X70
X60
Carte régulation
PAC
Interface COM
3
4
5
1a
1b
Handle in low position (DHW)
Handle in low position (DHW)
2
Heat pump
UHJXODWLRQERDUG
Gas regulation
ERDUG
Fan
COM
interface
COM
interface
2&,
Heat pump
UHJXODWLRQE
oard
COM
interface
Installation and commissioning instructions "1485 - EN"
- 43 -
Heat pump alféa hybrid duo gas