Connecting the Auto Wash 365 to the Optional Milk Lock Proximity Sensor
Connecting from the Plantwasher Input/Output Printed Circuit Board (PCB)
+ve - Brown - Connect into connection number 20
-ve - Blue - Connect into connection number 21
Signal - Yellow (1) - Connect into connection number 37
Signal -Yellow (2) - Connect into connection number 36
Connecting into the Proximity Sensor
+ve - Brown - Connect into connection number 1
-ve - Blue - Connect into connection number 2
Signal-Green/Yellow - Connect into connection number 3
Plantwasher
Input/Output
Board
49
30
31
32
33
16
17
18
19
20
21
22
23
26
27
28
29
24
25
37
35