Table of Contents
Modes of Relay Operations
............................................
3
LED Indication Description
..............................................
3
Operational Thresholds
...................................................
3
Typical Wiring Diagram
…….. ...........................................
4
Option 1 Diagram
.............................................................
5
Option 2 Diagram
.............................................................
5
Option 3 Diagram
.............................................................
5
Option 1 Starting Sequence
............................................
6
Option 2 Starting Sequence
............................................
7
Option 3 Starting Sequence
............................................
8
Manual Off Auto Switch Options
...................................
9
Fault Shutdown Conditions
.............................................
9
Automatic Starting for Battery Charging
....................
10
Generator Emergency Shutdown
.................................
10
LED Description and Meanings
.....................................
11
Specifications
..................................................................
11
Remote RV Generator Start Drawing
....................
12
Outback Inverter/Generac RV Gen. Drawing
......
13
Outback Inverter/Onan RV Gen Drawing
.............
14
Samlex EVO Inverter/Kubota GL Drawing
...........
15
Limited Warranty
.........................................................
16
Not Included…….
Outback 48 Volt inverter
systems require isolation relay
A0365
Features & Applications
Inexpensive 2 wire to 3 or 4 wire start controller
for electric start 3 or 4 wire diesel generators
Optimized for use with Outback Invertors
Supports three types of 3 or 4 wire generator
control: Momentary, Maintained & Ignition
Fixed crank time, over and under Hz
shutdown, and optional battery charging
thresholds
Maximum auto-start run time limit (6 hours)
Remote run and fault indication included
ABS epoxy sealed for harsh environment operation
Solving your generators 2 to
3 or 4 wire start-stop problem.
Description
The GSCM-mini-d is a micro-processor based generator
start-stop module, designed to auto start-stop diesel
generators that need a 3 or 4 wire connection from a 2
wire 12 volt or dry contact manual start command. The
GSCM-mini-d automatically disconnects the starter
when it either receives a remote start indication lamp
signal (
connected to terminal 8
) or an AC Hz signal from
the generator (
AC connected to terminals 9 & 10
).
Various LEDs are blinked or turned on to indicated the
run or fault status of the GSCM-mini-d. Manually
resetting the GSCM-mini-d by removing the power and
removes any lockout that allows the generator to
restart if called to do so.
The GSCM-mini-d is powered by 12VDC from the
generator battery and can monitor the battery voltage
and start the generator to charge its own battery if
connected to pin 4. The GSCM-mini-d is a limited
function controller that is part of the GSCM family.
All auto start battery voltage thresholds are
fixed, if adjustability is required use the GSCM
full function Generator Start Control Module.