Startup sequence 

At  startup, the  TM2D-HP  transmits 5  frames  spaced  one  minute  apart,  with  a  test  counter  0x0501, 0x0502,  up  to 
0x0505. 
 
6th frame transmitted is a keep alive frame. 
 
The 7th frame is an application frame containing a temperature and the header 0x1A. This contains the temperature, 
but no information on its relative position toward thresholds. 
 
Then the application frames will have the headers 0x53 à 0x5B. 

 

 

Summary of Contents for ACW/LW8-TM2D-HP

Page 1: ...Concerned models ACW LW8 TM2D HP ACW LW8 TM2D HP 5 ACW SF8 TM2D HP ACW SF8 TM2D HP 5 ATIM Cloud Wireless Digital temperature sensor with contact probes TM2D HP User Guide...

Page 2: ...as Periodical in the configuration tool 12 b Energy Saver mode 13 ACW configuration tool 14 a What version of the ACW configuration tool should you use 14 b Configuring the LoRaWAN network pairing mo...

Page 3: ...l Upper threshold probe 2 22 m Temperature offset probe 2 22 n Delta in confort zone probe 2 22 Connecting the modem 23 Accessing data on the web Sigfox and LoRa solutions 24 a Viewing probes on the...

Page 4: ...2020 Corrections MD Disclaimer The information contained in this document is subject to change without warning and does not represent a commitment on the part of ATIM radiocommunications ATIM radioco...

Page 5: ...and EN300 220 1 v2 4 1 Environmental recommendations Explosive atmosphere Except for the ACW ATEX line specifically intended for this purpose do not use ACW radio modems in the presence of flammable g...

Page 6: ...ean Union This symbol appears on a product or its packaging to indicate that the product may not be discarded with another household waste Rather it is your responsibility to dispose of this product b...

Page 7: ...l Housing IP 65 Power supply 2 battery packs 14 4 Ah Weight 280 g Frequency 865 870 MHz Power 25 mW 14 dBm Rate Sigfox 100 bps LoRaWAN 300 bit s 10 Kbit s Consumption Sigfox LoRaWAN Tx mode 60 mA 50 m...

Page 8: ...7 ATIM_ACW TM2D HP_UG_EN_V1 2 Housing a Space requirements Maximum cable diameter through cable gland 7 mm...

Page 9: ...lift the inside tab see photo Then pull on the back panel to separate the two parts of the housing c Mounting to a support ACW modems can be mounted on a flat wall a tube or pole or a DIN rail depend...

Page 10: ...dems the communication keys are automatically provided by the network pairing via Over The Air Activation or OTAA Each ATIM ACW product line has a QR Code label visible either on the side or on the fr...

Page 11: ...eading this code indicates the following information ATIM ACW XXX TM2D HP X X 190114 1 3 0 5 11 XXXXXXXXXXXXXXX Interpretation ATIM ACW XXX TM2D HP X X 190114 1 3 0 5 11 XXXXXXXXXXXXXXX Manufacturer n...

Page 12: ...ot right against the wall ideally at least 20 cm away The cables must be no longer than 10 m and must be shielded For optimal results we recommend that you place it high up and at least 1 meter away f...

Page 13: ...sent on a regular and periodic basis This makes it possible to obtain a very precise monitoring curve In this mode each reading is sent out by the ACW TM2D HP In other words the sampling period is equ...

Page 14: ...r than the maximum value specified by the user If an alert threshold is crossed a frame is sent out when the temperature reading leaves or re enters the comfort zone Example of operation in Energy Sav...

Page 15: ...ttps www atim com download 7887 When the ACW Configuration Tool is started the stand by window appears on the screen Click Help at the top left of the window then click About to view the version numbe...

Page 16: ...the module starts up or requests a connection This is the mode that is configured by default ABP Activation By Personalization In this mode the communication keys used are the ones loaded on the modu...

Page 17: ...mode of operation Difference in C vs last reading sent If outside range send an alert Frequency of transmission to network Lower threshold Upper threshold Offset applied to each reading and to the di...

Page 18: ...mperature offset of probe 1 0 C Lower threshold of probe 1 20 C Upper threshold of probe 1 40 C Temperature offset of probe 2 0 C Lower threshold of probe 2 20 C Upper threshold of probe 2 40 C Parame...

Page 19: ...perature sensor 1 Digital temperature sensor 2 Temperature S1 upper threshold and temperature S2 lower threshold 89 0x59 Digital temperature sensor 1 Digital temperature sensor 2 Temperature S1 upper...

Page 20: ...a test counter 0x0501 0x0502 up to 0x0505 6th frame transmitted is a keep alive frame The 7th frame is an application frame containing a temperature and the header 0x1A This contains the temperature b...

Page 21: ...ry 10 min 0x05 every hour 0x0A every 2 hours 0x0B every 4 hours 0x0C every 8 hours 0x06 every day 0x0D every 2 days 0x0E every 3 days 0x0F every 4 days 0x07 every week 7 days 0x08 every month 30 days...

Page 22: ...ABP Activation By Personalization OTAA Over The Air Activation h Delta for comfort zone probe 1 Parameter code Byte 1 Parameter value Byte 2 0x10 0xYY For a delta in C with a precision in tenths of a...

Page 23: ...threshold in C with a precision in sixteenths of C 0xYY and 0xZZ are calculated as follows 0 10000 625 Threshold must fall between 55 0 C and 125 0 C m Temperature offset probe 2 Parameter code Byte...

Page 24: ...perature probe Number Signals to be wired Description 1 GND S1 Ground for probe 1 2 Power S1 Power for probe 1 3 Data S1 Data for probe 1 4 Power S2 Power for probe 1 5 Data S2 Data for probe 2 6 GND...

Page 25: ...m to access all your devices and view your data Your login credentials will be emailed to you when we send out your order The My Groups page shows location data for all your devices after installation...

Page 26: ...we will take care of registering your modem probe sensor on the Sigfox network However if you have set up your subscription through Sigfox you will need to register your device yourself through the S...

Page 27: ...W TM2D HP_UG_EN_V1 2 Step 1 Open a Web browser and go to https backend sigfox com Enter the login name and password you selected when you created your Sigfox customer account Step 2 Click Device at th...

Page 28: ...ce that you want to register in your Sigfox account Your product is now being imported to your Sigfox account The import may take several hours Sigfox identifier Sigfox PAC code Sigfox certificate num...

Page 29: ...TAA is available on the ACW Configurator interface It is advisable to use the OTAA mode simpler Parameterized in OTAA when powering on a call request join request with a LoRa network is issued The dev...

Page 30: ...is correctly connected to the modem Check whether the modem has been registered on the network Check whether radio network coverage is available Check whether the blue and green lights flash during t...