23
ATIM_ACW-TM2D-HP_UG_EN_V1.2
Connecting the modem
The ACW-TM2D-HP modem is equipped with an external digital temperature probe.
Number
Signals to be wired
Description
1
GND S1
Ground for probe 1
2
Power S1
Power for probe 1
3
Data S1
Data for probe 1
4
Power S2
Power for probe 1
5
Data S2
Data for probe 2
6
GND S2
Ground for probe 2
7
nc
nc
8
nc
nc
Data Probe 1
Alim Probe 1
GND Probe 1
GND Probe 2
Data Probe 2
Alim Probe 2