20
Description of device / spare parts
H1
-
H4
No. Denomination
Order-No.
No. Denomination
Order-No.
1
Stand - rear
28 Fixing brackets for extractor hood
-
2
Stand - side
29 Adjusting screw for depth of cut
363865
3
Hexagon socket screw M6 x 10
30 Adjusting screw for blade shaft guard
holder
363872
4
Stand - front
}
363902
31 Push
stick
-
5 Tools
cpl.
363884
32 Open-end spanner SW 8/10
-
6
Hexagon socket screw M8 x 16
-
33 Cutting
blade
-
7
Guide plate guideway
-
34 Clamping screw
361110
8
Mushroom head square neck screw
-
35 Lever for thicknessing adjustment
-
9
Hexagon socket screw M8 x 20
-
36 Safety
label
363880
10 Guide
carrier
-
37 Hexagon socket screw key (Allan key)
SW 6
-
11
Spacer plate
-
38 Hexagon socket screw key (Allan key)
SW 5
-
12
Locking lever for guide plate holder
-
39 Hexagon socket screw key (Allan key)
SW 4
363742
13 Guide
plate
363862
40 Angle
adjustment
scale
-
14
Mushroom head square neck screw
-
41 Driving
belt
-
15
Locking lever for guide plate
-
42 Driving
belt
-
16 Exhaust
neck
363889
43 Driving
belt
-
17 Extraction
hose
363895
44 Roller
chain
363892
18 Hose
clip
363893
45 Depth-of-cut
scale
363891
19
Shavings bag
363890
46 Clamping device
363882
20 Motor
protection
switch
-
47 Blade shaft
363908
21
EMERGENCY-STOP button
-
48 Gearbox
cover
363864
22
ON / OFF-switch
-
49 Backstroke protection
363881
23
Blade shaft guard
363888
50 Draw in roller
-
24
Locking wheel
-
51 Draw out roller
-
25
Crank for height adjustment
-
52 Hexagon socket screw key (Allan key)
SW 3
-
26
Scale for height adjustment
363875
53 Setting gauge for the cutting blades
-
27 Extractor
hood
363876
-
Possible faults
Before each fault elimination:
−
switch off device
−
Wait until the machine comes to a stop.
−
Pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Fault Possible
cause Remedy
Machine fails to start after
switching on or switches off during
idle running
•
Power failure
•
Extension cable defect
•
Motor or switch defect
•
Check the fuse.
•
Check cable, no longer use defect cable
•
Have motor or switch checked by an
approved electrician or replaced by original
spare parts