CONTENT, WEIGHT AND PACKAGING DIMENSIONS
The appliance is delivered packaged in a wooden cage with appropriate protection. See table below for size.
Dimensions in mm - Weight in kilograms: Kg
WHC400
WHC500
WHC700
WHC900
A
820
820
1030
1030
B
1100
1100
1300
1300
C
1740
2100
1800
2170
Weight
with
packaging
203
229
259
297
5.
APPLIANCE CATEGORIES
These appliances are classified as: "Condensing gas fired storage water heaters".
Gas Categories: I2H, I3P I2L and derived second categories
TYPE C Appliance classes (EN 483) (see table):
C63
appliance
connected to an air intake and flue outlet
approved system and sold separately; the fan is upstream of
the heat exchanger.
C53
appliance connected to
two points having a different
pressure; the fan is upstream
of the heat exchanger.
C33
appliance connected to
coaxial or twin pipe flue
system so close to have the
same vertical wind conditions
(roof) with fan upstream of
the heat exchanger.
C13
appliance connected to
coaxial or twin pipe flue
system so close to have the
same wind conditions
(horizontally through the
wall) with fan upstream of
the heat exchanger.
C43
appliance connected to
coaxial or twin pipe flue
system so close to have the
same wind conditions, which
intakes air from the chimney
and with fan upstream of the
heat exchanger.
C83
appliance connected to
twin pipe flue system with air
intake from the outside and
flue outlet through the
chimney; the fan is upstream
of the heat exchanger.