background image

4/16 

 

 

 

equipment is to used properly and according to its ratings, documentation and local applicable 
laws. Local, national certificates of these units may exist outside the region of EU. 
 
The  aforementioned  Slam®Hornet  types  are  certified  as  follows.  You  may  find  brief 
explanation of the certificates beneath: 
 
Slam®Hornet luminaires with fluorescent tubes: 
 

CE

0537

 

 II 2 GD  

Ex emb IIC T3 Gb 

 

Ex tb IIIC T 90 °C Db  
 

 

Slam®Hornet luminaires with LED module: 
 

CE

0537

 

 II 2 GD  

Ex emb op is IIC T4 Gb 

 

Ex tb op is IIIC T 90 °C Db  
 

 

CE

0537

 = Valid production quality system approved and notified by VTT (Finnish Notified Body, 

listed by EC) 
 

 = Certified for explosion hazardous areas 

II

 =  Certified for use in areas excluding mines 

=  Equipment category (suitable for Zone 1&21 and Zone 2&22) 

G

 = Certification taking account explosion hazardous GASES 

D

 = Certification taking account explosion hazardous DUSTS 

 
Explanation of marking for explosion hazardous area due to Gases (e.g  Ex emb IIC T3 
Gb)

 

:  

 
Ex

 = Certified for use in explosion hazardous areas 

e

 =    Explosion protection method increased safety (of certain components) 

mb

  =  Explosion  protection  method  encapsulation  (encapsulating  ignition  sources  e.g. 

electronic ballast) 

op is

 = Explosion protection method optically inherently safe (visible or infrared radiation that 

is incapable of producing sufficient energy under normal or specified fault conditions to ignite 
a  specific  hazardous  athmosphetic  mixture).  This  definition  is  analogues  to  the  term 
“intrinsically safe” applied to electrical circuits 
 

IIC

 = Equipment group (including explosion hazardous areas of IIA, IIB and IIC gases) 

T3

 = Maximum inside temperature of the unit is 200 °C (within the ambient temperature range 

of    -20°C - +40°C) 

T4

 = Maximum inside temperature of the unit is 135 °C (within the ambient temperature range 

of    -20°C - +40°C) 

Summary of Contents for Slam Hornet 1 LED A

Page 1: ...08 ATEX 066 or IECEx VTT 12 0009 Thank you for choosing Slam Hornet portable work light for your job site Purpose of this manual is to provide you all the necessary safety and product information to...

Page 2: ...IA IIB or IIC in accordance with Equipment group IIA IIB or IIC 8 2 1 4 Temperature class of the equipment 9 2 1 5 Environmental criteria 9 3 Operating instructions 10 3 1 Personnel 10 3 2 Visual Insp...

Page 3: ...et 2 LED Slam Hornet Linear 2x18W Slam Hornet Linear 2x36W Slam Hornet Linear 2 LED Dimensions mm Product model L Slam Hornet 1x18W 335 115 Slam Hornet 1x36W A Slam Hornet 1 LED A 540 115 Slam Hornet...

Page 4: ...sion hazardous GASES D Certification taking account explosion hazardous DUSTS Explanation of marking for explosion hazardous area due to Gases e g Ex emb IIC T3 Gb Ex Certified for use in explosion ha...

Page 5: ...ation or during expected malfunctions 1 3 Standard unit construction The following list familiarizes you with some common unit features important to recognize End parts Flexible plastic made end parts...

Page 6: ...nts of own Socket Optional in built sockets receptacles for linking the Slam Hornet units in series apart from CSH118 Other common accessories Antistatic protective film for PC tube against chemical s...

Page 7: ...5 ohm High voltage test electrical strength The purpose of this test is to measure leakage current trough insulation Vital test for revealing broken components or similar failures which can not be ide...

Page 8: ...t category For explosion hazardous areas there are three equipment categories Category 1 product is suitable for use in Zones 0 1 and 2 20 21 and 22 Category 2 product is suitable for use in Zones 1 a...

Page 9: ...ntioned in this instruction are Temperature Class T4 GASES Slam units with fluorescent tube and LED modules mentioned in this instruction are having maximum surface temperature of 90 C DUSTS 2 1 5 Env...

Page 10: ...be used together with step down transformers Using Slam Hornet unit with transformers of 2 pole socket outlets without earthing bonding imposes certain extra requirements for the unit itself All the e...

Page 11: ...king capacity of at least 1500 A Earth Leakage Circuit Breaker ELCB It is recommended to use a supply with 30 mA ELCB Please observe the type label for further data Luminaires for 110 VAC or 230 V sup...

Page 12: ...is only for chaining Slam Hornet units 5 Fix them with accessories you have selected 6 Take the chain into Ex area Amount of lights which may be connected with each other depends on the supply voltage...

Page 13: ...net control gear protects itself against excessive voltage drops numerous linking by switching itself off If too many units are connected to the chain some units of the chain will switch off You may s...

Page 14: ...needed for measuring surface resistance of the PC tube 5 Maintenance instructions with exploded view diagram and spare parts list are available at your local distributor and the manufacturer Please wh...

Page 15: ...Gas Atmospheres Please observe the requirements of the valid standards of the day Please study at least the following standards EN IEC 60079 14 Electrical installations in hazardous areas EN IEC 60079...

Page 16: ...16 Helpdesk Under any doubt or question please contact your local distributor or the manufacturer Contact details Phone 358 20 734 3250 Fax 358 20 734 3299 Email info atexor com Web http www atexor c...

Reviews: