3.1.1 

Connect the charging gun to the charging device. If gun

 

A is used, click A on the standby 

interface, If gun

 

B

 

is used, click B on the standby interface.

b) Storage

 Transaction data is stored in non-volatile memory as records.

Ensure that the data stored correctly, continuously, completely and effectively.

 Keep not less than 10,000 records of space, the transaction records will be stored, the charger 

can promptly prompt for data acquisition.

2.2.6 Billing function

Support APP payment. 

2.2.7 Control function

Charge monitoring unit can adapt to a variety of charger operation, to achieve constant current 

limit voltage charging 

 constant voltage limit current charging 

 stop charging, the correct 

charging process.

2.2.8 Alarm function

Charger DC output anomalies, rectifier unit alarm / fault, DC output over / under voltage, DC 
output overcurrent, charger input switch trip / fuse blown, charging monitoring unit 
communication interruption, monitoring unit fault, etc, the monitoring unit can sound and light 
alarm, and display fault information on HMI.

2.2.9 Event recording function

Charger fault, charging start / end time, etc. all have event records, which is stored in non-volatile 
memory.

2.2.10 Operation authority function

The DC charger has operation authority password management function. The administrator can 
set parameters and check the charging data with the password.

2.2.11 Time-correction function

The charger can receive the right time command of the zone monitoring terminal to meet the 
requirements of PPS (second pulse) and PPM (minute pulse).

2.2.12 Protection function test

a) Output over-voltage protection
Turn off the output when the output voltage is greater than or equal to the set voltage value.
b) Overcurrent protection
Turn off the output when the output current is greater than the set current value.
c) Open circuit protection
Charger will shut down automatically in case of short-circuit fault; It can automatically resume 
work after troubleshooting.
d) Plug out under load protection
Unplug  the  plug  in  the  charging  state,  the  corresponding  contactor  protection  circuit 
immediately disconnected, at the same time the charger cut off the power supply to the socket to 
achieve plug removal double protection.

 

3

Operation Instructions 

3.1 Operation process

3.1.2 

If  the  charging  mode  is  the  Plug

&

Charge  mode,  the  charger

 

will  directly  enter  the 

charging process and start charging. If the charging mode is the APP

/

R

FID mode

You need to 

swipe the card to charge or open the mobile app, Scan the QR code on the left side of the screen, 
Enter  the  charging  process  according  to  the  app  operation  instructions  and  start  charging. 
During  charging,  the  interface  of  charger  will  display  current  SOC  of  battery,  voltage,  current, 
electric quantity, charging time and remaining charging time.

Fig3.1.1 Home Screen

Fig3.1.2 Swipe the QR Code

3.1.3 

Click the menu button in the lower left corner to enter the pile setting interface.

10

9

Summary of Contents for EVD-300D

Page 1: ...ss Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China E info atesspower com W www atesspower com DC qu...

Page 2: ...Schematics Installation 4 Contents 1 1 Product introduction 1 2 Product Block Diagram two guns 1 3 The main parameters 1 4 Product performance and features 1 5 Product use environment 1 6 Product Sta...

Page 3: ...ly forbidden to use the charger if the following cases is found charging connector or charging cable defect charging cables cracks abrasion rupture or exposed etc If found please contact the staff imm...

Page 4: ...ng air inlet 1 2 Product Block Diagram two guns 1 3 The main parameters Tab2 Technical Data Sheet No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Item AC input voltage AC input current AC fre...

Page 5: ...y of air 5 95 Over head shelter is needed for outdoor installation Installation tilt does not exceed 5 Keep away from flammable and explosive materials 1 6 Product Standards Please refer to Annex2 2 M...

Page 6: ...rent capacity 20KA 2 2 Charger function introduction 2 2 1 HMI 1 Charge setting method Can choose automatic setting mode and manual setting mode a Automatic setting means charging is performed accordi...

Page 7: ...2 2 11 Time correction function The charger can receive the right time command of the zone monitoring terminal to meet the requirements of PPS second pulse and PPM minute pulse 2 2 12 Protection func...

Page 8: ...put the menuinterface Fig3 1 4 1 System parameter setting page Fig3 1 4 2 Network parameter setting page Fig 3 1 4 3 Protection parameter setting page Fig 3 1 4 4 Fault information display page Fig 3...

Page 9: ...peration you need to hear beep beep to remove the card otherwise it may cause the operation to fail When charging gun plugged in EV and charger lit the yellow light do not operate the charging gun to...

Page 10: ...put over voltage over current fault Solution Rotate the emergency button to release Check the SPD module and replace the damaged SPD module Stop using it wait for the grid voltage to resume normal and...

Page 11: ...Carefully read the parameters to select the appropriate transport and storage location Suggest that the user try to use forklift to move DC charger 4 2 2 Transport of charger without packaging 4 2 2...

Page 12: ...fastening 11 M10 screws recommended for fastening 11 M10 screws recommended for fastening 11 M10 screws recommended for fastening 9 M8 screws recommended for fastening 6 Packaging transportation and...

Page 13: ...stomer needs 2 Technical documents User Manual certificate warranty card factory inspection report Appendix Tab1 Technical standards and regulations No 1 2 3 Classification Emission Immunity LVD Stand...

Page 14: ...nd those concerned about the product In order to further understand and use this product the user s manual provides a detailed introduction to the functions installation operation and maintenance of t...

Reviews: