No.
Item
Unit
Technical
requirement
Remark
3. Protection features
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
Can be automatically
restored
Can be automatically
restored
Can be automatically
restored
200V-750V;0-200A
750-850V;0-176A
When overcurrent fault
disappears, the output can
be automatically restored
Input OV set value
Output OV set value
Output UV warning value
Output current range
(Dual Plug)
Phase loss protection
Output overcurrent
protection
Output short circuit
protection
Over-temperature
protection
Input UV set value
Adjustable
Adjustable
900V
Adjustable,
Minimum -5V
0~200
When the rectifier
input phase loss,
charger shutdown
for protection
Output is limited
gradually
Output short circuit,
output current is
limited gradually.
Over temperature
protection point:
105
℃
4. Detection accuracy
Output voltage detection
accuracy
Output current detection
accuracy
Temperature detection
accuracy
Output control
Control instruction
Level C
4.1
4.2
4.3
5. Control features
5.1
5.2
Surge
protection
Vac
Vac
Vdc
Vdc
A
Vdc
A
200
≤
Vo
≤
850,25
℃
200
≤
Vo
≤
850
,
Input340V
~
460V
10%
~
107% rated current,
25
℃
≤±
0.5%
≤±
0.2A
≤±
5
℃
Input voltage within the specified range, the rectifier
allows the output power of 300KW, the output
voltage of 200
≤
Vo
≤
850, the maximum output
current is 200A.
No command from charger controller for 5s will lead
to the shutdown of the rectifier unit to ensure safetly.
Surge current capacity 20KA.
2.2 Charger function introduction
2.2.1 HMI
1 Charge setting method:
Can choose automatic setting mode and manual setting mode.
a) Automatic setting means charging is performed according to the status and command of
battery BMS.
b) Manual setting means charging is carried out on the basis of credit, electricity energy, power,
etc. Guidance information can be found on HMI.
2
)
Display
a) Real-time display of charging voltage, charging current, SOC, charging time, billing, battery
information and other information.
b) Manual input is displayed during manual setting.
c) In the event of a fault, the corresponding message is displayed.
d) Corresponding information of different running status can be shown on HMI.
e) Can display battery information.
2.2.2 Parameter setting
operator enters the setting interface through the password and sets the parameters of over /
under voltage protection threshold, overcurrent protection threshold, IP, communication port.
etc.
2.2.3 Self test
1) Charger self-test when powering on, including charger status, real time clock, power, etc.
2) Fault information is indicated via indicator light and display, which is also recorded in the HMI
as history fault data.
2.2.4 Firmware update
Support remote and local software upgrade functions when there is master station monitoring
system, and support local upgrade function when there is no master station monitoring system.
2.2.5 Data transmission and storage
a) Transmission
The charger has data transmission interface to collect and upload charging information data as
well as charger fault data.
)
8
7