Appendix
157
Clear Login Information
If you are unable to perform an Administrator login (because the Username and
Password information has become corrupted or you have forgotten it, for
example) you can clear the login information with the following procedure.
Note:
Performing this procedure also returns all settings to their defaults.
To clear the login information (and return all settings to their defaults), do the
following:
1. Power off the Serial Console Server and remove its housing.
2. Use a jumper cap to short the mainboard jumper labeled
J11
(for
SN0132CO/SN0148CO as shown in the diagram below) or
J17
(for
SN9108CO/SN9116CO/SN0108CO/SN0116CO).
3. Power on the Serial Console Server.
4. When the LEDs flash, power off the Serial Console Server.
5. Remove the jumper cap from
J11
(SN0132CO/SN0148CO) or
J17
(SN9108CO/SN9116CO/SN0108CO/SN0116CO).
6. Close the housing and start the Serial Console Server.
After powering on the unit, you can use the default Super Administrator
Username and Password (see
, page 33), to log in.
Summary of Contents for SN01 CO Series
Page 34: ...Serial Console Server User Manual 20 This Page Intentionally Left Blank...
Page 45: ...Chapter 2 Hardware Setup 31 SN9108CO SN9116CO Installation Diagram...
Page 46: ...Serial Console Server User Manual 32 This Page Intentionally Left Blank...
Page 129: ...Chapter 8 Device Management 115 SN0108CO SN0116CO SN0132CO SN0148CO...
Page 138: ...Serial Console Server User Manual 124 Association The Association tab is currently reserved...
Page 152: ...Serial Console Server User Manual 138 This Page Intentionally Left Blank...