Installation Guide
GN0116 Guardian Over the NET™
www.aten.com
Page 1: ...Installation Guide GN0116 Guardian Over the NET www aten com ...
Page 2: ...e output voltage is 12VDC 50mA They can operate buzzers warning lights and other similar devices They can also be connected to an extension unit and used as programmable power outlets 9 Ports 1 2 and 3 4 are resistance type analog input ports The input resistance ranges from 2 205KΩ The ports have 1024 levels of resolution With appropriate drivers they can be connected to thermistor or other resis...
Page 3: ...ction If the Ethernet connection is used connect the network cable into the RJ 45 port to connect the GN0116 to the network Ì RS 232 Connection If you choose to use the RS 232 connection connect the RJ 45 connector on the bundled RS 232 to RJ 45 cable to the port marked as 232C on the panel and the RS 232 to the corresponding device Computer COM port or the MODEM port as the demonstrator is using ...
Page 4: ... Browser Log in directly using the IP address found by the Monitor program y ssConsole Bundled software that offers a specially designed user interface y External Guardian Monitor Center Server Installed on a server in the same network segment The administrator can manage the device through a browser Please see the User Manual for a description of each user interface Guardian Monitor Center GMC Th...
Page 5: ...configuration process the GMC software will find all GN0116 devices on the same network segment the notebook client can be used to view the status of all GN0116 ports Sensors Installation Ì As mentioned in the Front View Rear View introduction the GN0116 mainly uses the four RJ 45 ports on the rear panel to connect to sensors or other devices Up to eight Digital Output ports 101 108 two Digital In...
Page 6: ...s demonstration three sensor alert devices were chosen Smoke Detector Beeper and Reed Switch Smoke Detector Beeper Reed Switch As the sensors are connected to the GN01167 via a RJ 45 port a UTP cable with the RJ 45 connector is needed to connect the sensors To make the connection strip the UTP wiring then connect each wire to their respective sensor Please see the attached wire PIN reference table...
Page 7: ...following models EA2110 1 x AC Current Sensor and 1 x Humidity Sensor EA2210 2 x AC Current Sensors EA2310 1 x AC Current Sensor and 1 x AC Voltage Sensor EA2110 Current Detector The EA2110 package includes one set of AC Current Sensor Cable You can connect the clip on sensor device on one end of the cable to the power wire in the power distribution box or strip the AC power cable and then clip it...
Page 8: ...r can also be used to detect humidity Lock it into place Once the sensor has been secured use an UTP cab connect the EA2210 s RJ 45 port to the GN0116 Use the Port 31 32 voltage type Analog Input Port when conn Note Connecting to the wrong port may damage your system Once the EA2110 has been installed the clip on sensor GN0116 Guardian Over the NET Installation Guide ...
Page 9: ... g Server to the power outlet on the EA2310 Use the bundled power ca to the AC power source Once the power source and device are both conne use a UTP cable to connec Use the Port 31 32 voltage type Analog Input Port when connecting to the GN0116 Note Connecting to the wrong port may damage your system Configuration Operation Ì Once the Sensors have been installed the pre configured Guardian Monito...
Page 10: ...ct Beijing China 100088 Phone 86 010 51294848 Fax 86 86 010 82961318 www aten com cn E mail sales aten com cn U S A Subsidiaries ATEN Technology Inc 23 Hubble Drive Irvine CA 92618 U S A Phone 1 949 428 1111 Fax 1 949 428 1100 www aten usa com E mail sales aten usa com ATEN New Jersey Inc 155 Pierce Street Somerset NJ 08873 U S A Phone 1 732 356 1703 Fax 1 732 356 1639 www aten usa com E mail sale...