background image

KK-MLC.010 19.02.21 Rev No:3 

 

 
 
Technical  Specification

 

 

 

 

Operation Temperature 

- 25  to 

85 °C

 

Storage Temperature 

- 40 to  100 

°

Protection Class 

IP65 

Body  

Aluminum 

Magnetic  Tape Type 

B2 

Reading Tape Distance 

1,5 mm  

Opertaion Speed  

3 m/s max. 

Connection  

D-Sub 9 Pin, 5 or 8 x 0,14 mm

2

 shielded cable 

Accuracy  

± 

40 

µ

Repeataibility  

± 1 pulse

 

 

 
ELEKTRICAL SPECIFICATIONS

 

 

 

 

Power Supply 

5 Vdc, 

+10 Vdc…+30Vdc

 

Current Supply 

40 mA/per channel max. 

Output Type 

TTL, Push Pull Line Driver 

Output  Signal 

A, /A, B, /B, Z, /Z 

Output Current 

40 mA/per channel max. 

Immunity 

EN-61000-6-2:2005 

 

DIMENSIONS 

 

 

Standard Measuring  

Lengths *

 

100 

120 

150 

170 

200 

220 

250 

270 

300 

320 

350 

370 

400 

420 

450 

470 

500 

520 

550 

570 

600 

650 

700 

750 

800 

850 

900 

950 

1000  1100  1200  1300 
1400  1500  1600  1700 
1800  2000 

 

 

 

3.

 TECHNICAL SPECIFICATION

 

 

Summary of Contents for MLC 420

Page 1: ...e Values up to 2000 mm Socket Building Perfect Retention System High Stability IP65 Protection Class Easy Installation Same Ruler Available Right or Left Delem Cybelec and ESA Compatible with Devices OPERATION MANUAL MAGNETIC LINEAR SCALES MLC 420 PORTABLE REFERENCE POINT ...

Page 2: ...KK MLC 010 19 02 21 Rev No 3 1 ...

Page 3: ...h line 7 The magnetic tape must be away from magnetic areas 8 The proximity of the band with comparator magnet or similar instruments having a magnetic effect disrupts the working structure of the band 9 Don t make any connection when the scale energized 10 Please call the service for any problem about the scale 11 Transport and storage should be at their original packaging and an ambient temperat...

Page 4: ...nal output type 2 A B 3 A B Z 4 A A B B 6 A A B B Z Standard single Z referance signal Optional Z signal at every 2 mm Model Cable Length 3M 3 meters 3 5M 3 5 meters 4M 4 meters 5M 5 meters 6M 6 meters 7M 7 meters 8M 8 meters 9M 9 meters 10M 10 meters 15M 15 meters Please ask for other options Power Supply and Output TTL 5VDC Supply Voltage 5 VDC TTL RS422 Line Driver Signal Output PP 10 30 VDC Su...

Page 5: ...e Accuracy 40 µm Repeataibility 1 pulse ELEKTRICAL SPECIFICATIONS Power Supply 5 Vdc 10 Vdc 30Vdc Current Supply 40 mA per channel max Output Type TTL Push Pull Line Driver Output Signal A A B B Z Z Output Current 40 mA per channel max Immunity EN 61000 6 2 2005 DIMENSIONS Standard Measuring Lengths 100 120 150 170 200 220 250 270 300 320 350 370 400 420 450 470 500 520 550 570 600 650 700 750 800...

Page 6: ...the sensor output signals is given If the control circuit is suitable in the Line Driver sensors the output signal inverts A B Z must be included in the system If the control circuit is not suitable for this application A B Z signal cables must be immobilized seperately isolated Don t forget that there are also currents on these cables A A B B B Z Z 90 Phase Optional Every 2 mm Z Pulse Standard On...

Page 7: ... Change the cable 1 and protection cover 2 places And close the connector 1 2 The connector is put on its place The screws is closed again by Phillips screwdriver Anymore the cablo is on the other side The set screw screwdrivers of top installation head are loosened with 3 mm allen and top connection head is removed The top installation head that is removed is screwed to the sensor s other side wi...

Page 8: ...whole distances The scale and reader head body should be set with the proper equipments like comparator during the montage stage EXAMPLE OF THE MLC 420 R L RIGHT AND LEFT SENSOR APPLICATION 4 3 Montage Max 0 2 mm deviation can be 0 2 Max 0 2 mm deviation can be 0 2 KEEP AWAY FROM THE STRONG MAGNETIC AREA PRESS BRAKE Control Panel D Sub 9 Pin Connector D Sub 9 Pin Connector Reference Reference Atek...

Page 9: ... 4 PINK Z 5 GREEN B 6 WHITE B 7 GREY Z 8 BLUE A 9 Pin Number Cable Color Signal 1 PINK Z 2 GREEN B 3 YELLOW A 4 5 BLACK GROUND 6 GREY Z 7 WHITE B 8 BLUE A 9 RED POWER SUPPLY Pin Number Cable Color Signal 1 BLACK GROUND 2 BLUE A 3 WHITE B 4 GREY Z 5 RED POWER SUPPLY 6 YELLOW A 7 GREEN B 8 PINK Z 9 Pin Number Cable Color Signal 1 PINK Z 2 GREY Z 3 RED POWER SUPPLY 4 5 BLACK GROUND 6 YELLOW A 7 BLUE ...

Page 10: ...or Signal 1 YELLOW A 2 BLUE A 3 4 PINK Z 5 GREY Z 6 7 8 BLACK GROUND 9 10 GREEN B 11 WHITE B 12 13 14 15 RED POWER SUPPLY Pin Number Cable Color Signal 1 YELLOW A 2 BLUE A 3 GREEN B 4 WHITE B 5 PINK Z 6 GREY Z 7 8 9 RED POWER SUPPLY 10 11 BLACK GROUND 12 13 14 15 SHIELD GND ...

Page 11: ...KK MLC 010 19 02 21 Rev No 3 10 ...

Page 12: ...02 21 Rev No 3 11 ATEK ELEKTRONİK SENSÖR TEKNOLOJİLERİ SANAYİ VE TİCARET A Ş Gebze OSB 800 Sokak No 814 Gebze KOCAELİ TURKEY Tel 90 262 673 76 00 Fax 90 262 673 76 08 Web www ateksensor com E Mail info ateksensor com ...

Reviews: