KK-MLC.010 19.02.21 Rev No:3
7
Installation the MLC 420 is an important point in terms of the proper system function. The reader head is bearded in
the profile, the distance between the profile and reader head is constant. The parallelism between the reader head
and profile should stay same during the whole distances. The scale and reader head body should be set with the
proper equipments like comparator during the montage stage.
EXAMPLE OF THE MLC 420 R&L (RIGHT AND LEFT) SENSOR APPLICATION
4.3. Montage
Max 0,2 mm
deviation can be.
0,2
Max 0,2 mm
deviation can be.
0,2
KEEP AWAY FROM THE STRONG MAGNETIC AREA
PRESS BRAKE
Control
Panel
D-Sub 9 Pin
Connector
D-Sub 9 Pin
Connector
R
e
fer
e
n
ce
R
e
fer
e
n
ce
A
tek
WARNING !!!
When you are changing the cable place, pay attention to the arrow (1) must be like the figure.
1