Hardware installation & connection
5
Cascade with multiple devices
Cascade with multiple PPM-AS/CD-8AS/CD-16AS/URC-150AS devices:
To know the 8-pin STP CAT5/6 pinout using on URC-150AS, see
Up to ten PPM-AS units can be connected via junction boxes on one IDA8.
8-pin STP CAT5/6 cable
8-pin STP CAT5/6 cable with metal shielded connector
Pin1
RS-485 B
Pin2
RS-485 A
Pin3
Line in -
Pin4
24VDC
Pin5
Ground
Pin6
Line in +
Pin7
Line out -
Pin8
Line out +
IDA8C LCD panel
The LCD touch panel on IDA8C processor provides system programming, control, paging, monitoring and
system status display.
Login & network settings
1. Set the IP, subnet mask and gateway address from LCD touch panel of IDA8C.
The default factory setting of the IP address is 192.168.100.236.
2. You need to login the menu on IDA8C first, then continue to set the IP/Subnet Mask/Gateway.
3. Press [SYSTEM SETTING] in [MAIN MENU] page.
4. Press [LOGIN] in [SYSTEM SETTING MENU-1] page.