background image

Contact infomation

13

Contact infomation

 ATEÏS Europe B.V. 

 Europe & Africa 

www.ateis.com

Celsiusstraat 1 - 2652 XN Lansingerland

 (Rotterdam Region), Netherlands

Tel: +31 (0) 10 2088690

[email protected]

 ATEÏS Suisse SA 

 Switzerland & South-East Europe 

 Penton Audio USA 

 USA, Canada & Latin America 

Avenue des Baumettes 9, 

1020 Renens VD, Switzerland

Tel: +41 (0) 21 881 25 10

[email protected]

21 Sabin St. Pawtucket,

RI 02860, USA

Tel: 401-727-1600

Fax: 401-727-0003

[email protected]

 

 ATEÏS France S.A.S 

 France 

 ATEÏS SE Europe 

 Serbia 

8, rue de l'Europe - 

ZA de Font Ratel,

38640 Claix, France

Tel: 33 (0) 4 76 99 26 30

[email protected]

Sime Lukina Lazica 12-B, 

11040 Belgrade, Serbia

Tel: +381 (0)11 40 89 617

[email protected]

 Penton UK Ltd. 

 UK & Ireland 

 Xavtel Communications RUS Ltd. 

 Russia 

Unit 2, Teville Industrials, Dominion Way,

Worthing West Sussex,

BN14 8NW, United Kingdom

Tel: +44 (0)1903 215315

Fax: +44 (0)1903 215415

[email protected]

Russian Federation, 115280, Moscow

Leninskaya Sloboda str., 26 bld. 28, Business

Center "Slobodskoy", office #122

Tel: +7 495 803 3655

Fax: +7 495 803 3655

[email protected]

 ATEÏS Middle East 

 ATEÏS China 

Light Industrial Unit 11 Dubai 

Silicon Oasis, Dubai United Arab Emirates

Tel: +971 4 3262730

Fax: +971 4 3262731

[email protected]

Room 6-2, Yunheng Building,

No.1, Lane 1066, Sanwu Road,

    Luotuo Street, Zhenhai District, Ningbo, China

Tel: 0574-86559991

[email protected]

 ATEÏS SE PTE Ltd. 

 South-East Asia 

 ATEÏS Far East CORP. 

 Far-East Asia 

Blk 5002 Ang Mo Kio Avenue 5, #03-01B

TECHplace II. Singapore 569871

Tel: +65 6481 1968

Fax: +65 6481 1960

[email protected]

No.60, Xinghua 2nd Rd, Tanzi, 

Taichung 427, Taiwan
Tel: +886-4-25333820

Fax: +886-4-25333830

[email protected]

Summary of Contents for IDA8C-SW

Page 1: ...IDA8 TM Highly Integrated Networked Public Address and Voice Alarm System Installation Guide Global Net Revision History v1 02 www ateis com 2021 ATEÏS member of PAX ProAV Group ...

Page 2: ...pplies or power amplifiers Power supply Use the supplied AC power cable to connect the IDA8C IDA8C SW IDA8SAB IDA8SL unit to he power outlet and IDA8S unit by 24VDC The Power LED on the front panel will glow green when power is applied If 24VDC power and AC mains power are connected at the same time IDA8C IDA8C SW IDA8SAB IDA8SL will use AC power first and switch to DC power if there AC mains is n...

Page 3: ...tputs Z1 to Z8 Each zone output consists of 2 redundant loudspeaker lines line A and line B Normally the paging calls and BGM are distributed to a zone over both loudspeaker lines If one of the loudspeaker lines of a zone fails it is still possible to distribute the paging calls and BGM to the zone over the remaining loudspeaker line We recommend that the IDA8 controller connects to the floating o...

Page 4: ...DA8C If the distance between IDA8C and JB is more than 300m the JB requires to add an external power supply Connect with one device 1 Connect the JB to IDA8C processor via 8 pin STP CAT5 6 cable 2 Connect the PPM AS to JB via 10 pin CAT5 6 with metal shielded connector 3 Switch to MASTER switch on JB Connect the PPM AS CD 8AS CD 16AS to multiple JB for longer distance 1 Connect the JB to IDA8C pro...

Page 5: ...RS 485 B Pin2 RS 485 A Pin3 Line in Pin4 24VDC Pin5 Ground Pin6 Line in Pin7 Line out Pin8 Line out IDA8C LCD panel The LCD touch panel on IDA8C processor provides system programming control paging monitoring and system status display Login network settings 1 Set the IP subnet mask and gateway address from LCD touch panel of IDA8C The default factory setting of the IP address is 192 168 100 236 2 ...

Page 6: ...ult user ID of IDA8C keep the password field empty and click OK 7 And there will be a message indicates as Login successful 8 Go back to SYSTEM SET MENU 2 page and click ETHERNET 9 There are three fields IP ADDRESS SUBMASK and GATEWAY Change the settings to fit your network In this example we changed the IDA8C s IP to 192 168 100 79 ...

Page 7: ...Hardware installation connection 7 The settings will be applied after the rebooting the system ...

Page 8: ...ssign the network card on Ateis Studio Click Tools Communication to open the Network Adapter Setting window Select the network card in your PC laptop then click OK Step 2 search devices Search the Ateis device and connect to It Before searching the Ateis devices in LAN the device list will be shown in blank Now click Auto Search button under the Devices tab then click Clear button the device list ...

Page 9: ...ise continue the following steps to update the firmware The figure below shows an incompatible version of the firmware which is marked in red To update the firmware go back to Device Management window and click Update button After its setting window appears select the IDA8C and choose the firmware file asu from IDA8 directory See the picture as below Please find the update file from C Program File...

Page 10: ...es to restart the device Step 4 system building create a new file Create a new file Create a new file by clicking the button on the upper left of the Ateis Studio software Connect the device and create an IDA8C block in the device editor window Now Drag N Drop the device system into the configuration window The Set Audio Module window will appear click Create button to continue ...

Page 11: ...mponents which are listed on the left to the DSP configuration window And start to design the internal signal paths for each component via drag and drop Element adjustment Set the element of Tone Generator o Level dB 10 o Tone Button On o Tone freq Hz 2 00k Now you can see the channel 1 meter and hear a 2k tone from the speaker connected to the Amplifier Zone Output zone1 on the rear panel of the ...

Page 12: ...e system shall go online click Yes The settings could be modified and activated under Online mode Please read the IDA8 global net user manual to know the advanced configuration such as audio routing event and bell scheduler master sub preset 3rd party control EVAC paging paging with priority management monitor DSP parameter adjustment level control fault list user management etc on www ateis com D...

Page 13: ... Communications RUS Ltd Russia Unit 2 Teville Industrials Dominion Way Worthing West Sussex BN14 8NW United Kingdom Tel 44 0 1903 215315 Fax 44 0 1903 215415 sales pentonuk co uk Russian Federation 115280 Moscow Leninskaya Sloboda str 26 bld 28 Business Center Slobodskoy office 122 Tel 7 495 803 3655 Fax 7 495 803 3655 info xavtel ru com ATEÏS Middle East ATEÏS China Light Industrial Unit 11 Dubai...

Reviews: