VARENA
12
A73023342
ANTI-FROST:
PROGRAM:
CONFIGURATION:
To show the user that the radiator is heating there is a symbol of a thermometer being filled as
follows:
When the room temperature is below the temperature set point the radiator will turn the element
on to raise the room temperature.
I
n this mode, the temperature setting is
7 °C
and is factory set.
Anti-frost is usually used as an off set point and for long periods
of absence when you want to avoid freezing.
In
Program
mode, the radiator automatically switches between the 3 mode
temperatures according to the
daily and weekly program
set by the user.
The bar chart is displayed permanently and displays the 24-hour program divided
into one-hour intervals.
Each one-hour interval can be programmed as
comfort
,
eco
or
heating
off
.
The bar showing the current time flashes to indicate to the user what the current
set point is.
Economy mode is used for short absence periods to prevent the temperature
from falling excessively.
The configuration screen is at the end of the modes sequence, before entering the
initial comfort mode.
You can configure 4 parameters; the active parameter is flashing:
1 – Screen backlight level at rest,
from 0 to maximum (100%)
2 – Screen backlight time
from 1 s to 240 s
3 -
Open Window
Function
ON or OFF
4 -
Adaptive start control
function
ON or OFF
To modify a parameter, use the
-
and
+
keys. To move from one parameter to the
next, press the
OK
key. The system exits this mode by pressing the
mode
key at
any time, by waiting 30 seconds without pressing any key or by pressing the
OK
key on the last parameter.
MODE
MODE
MODE