ATC EcoMini EM Series Installation, Operation & Service Manual Download Page 21

 

Applied Thermal Control Ltd 

39 Hayhill Industrial Estate 
Barrow-upon-Soar, Loughborough 
LE12 8LD, United Kingdom 
+44 (0) 1530 839 998 
[email protected] 
[email protected] 

Operating Manual; Recommended Spares 

Annex M-1

 

 

 

DOCUMENT DETAILS 

Date  1/SEP/2020 

Compiled by  AMI 

Page  1 / 1 

Revision  1 

 

RECOMMENDED SPARES FOR ATC MINI (M-SERIES) AND ECOMINI (EM-SERIES) CHILLERS 

Recommended spares include all rotating machinery (i.e. motors, fans), all sacrificial elements (i.e. fuses) and 
parts that users interact with (dials, fittings). Pricing is available from [email protected]

 

COMMON TO BOTH MINI AND ECOMINI 

PN

 

Description

 

QTY

 

WA697 

Water Pump 

RA282 

Fridge Compressor 

RA282 

Compressor Controller 

EA787 

Compressor Cooling Fan 

RA287 

Fridge Condenser Fan 

EA512 

Power Inlet Fuse 

EA769 

Pump Fuse 

EA764 

DIN Rail Fuse Holder 

WA643 

Self-Sealing Water Bulkhead (SA00016) 

WA644 

Self-Sealing Water Connectors (SA00016) 

WA642 

12mm Push Fit Water Bulkhead  

WA652 

12mm Push Fit Plug 

EA044 

IEC Cordset 

EA770 

Power Inlet Connector Module 

MA310 

Rubber Mounting Feet 

WA641 

Fluid Tank Assembly 

 

COMMON TO MINI ONLY 

PN

 

Description

 

QTY

 

EA754 

Power Supply 

EA760 

USB Port 

EA755 

Touch Screen Controller NON-RS485 

EA778 

Touch Screen Controller WITH-RS485 

EA513 

Controller Fuse 

EA762 

Pump Relay 

EA759 

Optical Level Switch 

EA757 

Pressure Transducer 

EA586 

RTD Temperature Probe PT100 

RA285 

Solenoid Coil 

 

COMMON TO ECOMINI ONLY 

PN

 

Description

 

QTY

 

EA815 

Power Supply 

EA019 

NTC Temperature Probe assembly 

EA812 

Speed Control Potentiometer 

EA813 

Speed Control Dial 

EA816 

Low Temperature Cutoff Controller 

 

Annex M-1 200828 Recommended spares, Mini & EcoMini

21

Summary of Contents for EcoMini EM Series

Page 1: ...w upon Soar Loughborough LE12 8LD United Kingdom 44 0 1530 839 998 Service thermalexchange co uk Support app therm com Installation Operation Service Manual EcoMini EMxxn DOCUMENT DETAILS Date 28 AUG...

Page 2: ...Kingdom 44 0 1530 839 998 Service thermalexchange co uk Support app therm com Installation Operation Service Manual EcoMini EMxxn DOCUMENT DETAILS Date 28 AUG 2020 Author s MJH Page 2 5 Revision 1 CHA...

Page 3: ...C 4 to 35 Optional temp range C 10 to 65 Power supply requirement VAC 100 240 Hz 50 60 A 1 240VAC 2 115VAC Sound pressure level dB 64 Auto diagnostic functions Undertemperature cutout Overcurrent cut...

Page 4: ...user serviceable parts Repair and service requires specialized knowledge and tools to be provided by ATC or its local agent Any unauthorized tampering with the refrigeration system automatically inval...

Page 5: ...tallation Mini EcoMini Annex D 2 200828 EcoMini fill procedure Annex E 6 200826 Z31GS Controller Variable Resistor Annex F 1 191129 Pres flow in Mini with centrif pump Annex G 6 200828 EcoMini generic...

Page 6: ...You should inspect the packaging for signs of transit damage before signing for the unit and if possible unpack the unit before signing Once you have signed for the goods ATC cannot be held responsibl...

Page 7: ...ltage b Frequency of 47Hz to 63Hz inclusive c Maximum current draw of 5 8A 100VAC mains fusing is rated 6 3A accessible from rear i See product rating label for fuse specification ii Two modes of supp...

Page 8: ...Mini and EcoMini are supplied with quick release fittings by default either of the CPC or push fit variety The former of these have built in valves to prevent loss of fluid when disconnecting but oth...

Page 9: ...n water line and where the lid seals c Turn your attention to the power inlet rocker switch on the back of the chiller i Immediately after toggling this switch assuming that the power cord is connecte...

Page 10: ...ATION VALUE ON Z31 GS Navigation Upon first powering on the chiller will arrive at this display after a loading sequence is complete Process cooling will start automatically on the fridge and water ci...

Page 11: ...4 Regardless of the position of the speed dial the low temperature cutoff controller will stop the compressor if the process water temperature falls below its set value and will not start again until...

Page 12: ...are best served by the quieter and mechanically looser centrifugal types the flow of these items is dictated by the backpressure of the pipework through which it must pump Reviewing the pump flow cur...

Page 13: ...ing fan the compressor or the pump Pay attention to specific components to identify the source of noise If there is an air pocket within the water circuit or not enough liquid in the tank the pump cou...

Page 14: ...thly J F M A M J J A S O N D Check the condenser is free from dust or accumulation of debris Annually Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Drain process fluid and replace with fresh fluid Check for fluid leaks thr...

Page 15: ...ing fan blades continue to rotate Do not attempt servicing whilst the blades are rotating Warning All chillers contain water and electricity in close proximity Ensure the unit is isolated before servi...

Page 16: ...mber Commercial name As above NOTIFIED BODY Not applicable QUALITY ASSURANCE SYSTEM QMS International Ltd Muspole Court Muspole Street Norwich NR3 1DJ United Kingdom ASCB Registered 201409 2 DECLARATI...

Page 17: ...strate compliance upon request with the Conflict Minerals acts and guidelines ATC uses Gold and Tin in electrical components on PCBs and in rotating machinery as governed by technical requirements of...

Page 18: ...an be used in some uses but cannot be used in identified uses Applied Thermal Control has contacted all our suppliers and to the best of our knowledge none of the articles that we sell intentionally c...

Page 19: ...sks posed by these substances alone The European Parliament and Council issued regulation 2019 1021 on 20 JUN 2019 and further amended regulation 2020 784 on 8 APR 2020 POPs LISTED UNDER INITIAL REGUL...

Page 20: ...account Freight costs for shipping from ATC are for ATC s account During the second year of the warranty freight costs to and from ATC are for the customer s account d I m experiencing problems with...

Page 21: ...Condenser Fan 1 EA512 Power Inlet Fuse 2 EA769 Pump Fuse 1 EA764 DIN Rail Fuse Holder 1 WA643 Self Sealing Water Bulkhead SA00016 2 WA644 Self Sealing Water Connectors SA00016 2 WA642 12mm Push Fit Wa...

Page 22: ...d use SU21 Consumer uses Private households general public consumers Description Gas 1 3 Details of the supplier of the safety data sheet Company Harp International Limited Address Gellihirion Industr...

Page 23: ...medical attention if irritation or symptoms persist Eye contact Seek medical attention if irritation or symptoms persist Skin contact Frostbite treat as thermal burns Ingestion Ingestion is not consi...

Page 24: ...f ignition No smoking Do not eat drink or smoke in areas where this product is used or stored When using do not eat or drink Wash hands after handling the product 7 2 Conditions for safe storage inclu...

Page 25: ...Odour Slight Odour threshold No data available Freezing Point No data available Evaporation rate No data available Water solubility No data available Fat Solubility No data available Soluble in No dat...

Page 26: ...high temperature Thermal decomposition giving toxic and corrosive products Gaseous hydrogen fluoride HF Carbon oxides Decomposition temperature 370 C SECTION 11 Toxicological information 11 1 Informat...

Page 27: ...bal warming potential with respect to CO2 1430 IPCC Assessment Report 4 Ozone depletion potential Ozone depletion potential ODP R 11 1 Value SECTION 13 Disposal considerations 13 1 Waste treatment met...

Page 28: ...y amending Directive 1999 45 EC and repealing Council Regulation EEC No 793 93 and Commission Regulation EC No 1488 94 as well as Council Directive 76 769 EEC and Commission Directives 91 155 EEC 93 6...

Page 29: ...ician 4 2 Skin Contact Wash off immediately with plenty of water If skin irritation persists call a physician 4 3 Inhalation Remove to fresh air If symptoms persist call a physician 4 4 Ingestion Rins...

Page 30: ...Time Weighted Average TWA Particulate 10 mg m3 ELV IE Time Weighted Average TWA Total vapour and particulates 150 ppm 470 mg m3 ELV IE Time Weighted Average TWA Particulate 10 mg m3 8 2 Exposure cont...

Page 31: ...tion to the nose throat upper respiratory tract and lungs No deaths occurred 11 3 Dermal LD50 20000 mg kg rabbit Prolonged skin contact is unlikely to result in absorption of harmful amounts Skin irri...

Page 32: ...pty contaminated packaging thoroughly They can be recycled after thorough and proper cleaning Packaging that cannot be cleaned are to be disposed of in the same manner as the product 13 3 European Was...

Reviews: