(b)
Automatic Button Restoration (ABR):
The ABR feature releases locked-down buttons
when the handset is restored. The buttons may
be preset without removing the handset from
the cradle.
(c)
Line Recall:
An amber-capped recall
button provides switchhook flash without
releasing the buttons.
(d)
Intercom:
Two buttons are dedicated to
the intercom feature.
These buttons are
located on the right end of the 10-button key.
These buttons may be converted in the standard
manner to provide signaling or may be used for
CO/PBX lines. However, CO/PBX lines when
terminated at these positions will not be
conferencable.
3.
INSTALLATION
3.01
Assemble the required components to the
telephone set base.
Note:
On current production keys the cap
must be properly oriented to lock the cap into
the button.
3.02
Individual signaling may be provided by
converting a locking key button to nonlocking.
Remove the 812857738 (P-28E773) locking pin from
the button to be converted and modify per Table. B.
3.03
If an additional buzzer is required, plastic
screw grommets and mounting screws are
provided for installation. The additional KS-8109L2
or KS-20419L1 buzzer must be ordered separately.
3.04
Dial Restriction:
(1) 830-Type Telephone Set:
(a) Install a 533K (preferred), KS-21765Ll,
or 446F diode between terminals RR and
F of the network as shown in Fig. 6.
(b) Wire telephone set as shown in Table C.
(2) 2830-Type Telephone Set:
(a) Wire telephone set as shown in Table C.
(3) Installations as described above will restrict
dialing on all lines of the respective telephone
ISS
8,
SECTION
503-701-101
set. To permit dialing on selective lines reverse
tip and ring leads of the line involved at the
distribution terminal or 66-type connecting block.
When a 2A1 matrix block is used, the reversing
of conductors must be done on the telephone set
side of the matrix block.
(4) For additional information on dial restriction,
refer to Section 500-155-100.
3.05
Polarity guard (all 2830-type telephone sets
except the 2830DM; see 3.06) should be used
only when specified by local instructions for
end-to-end signaling installations where battery
and ground reversals may be encountered.
An
819041708 (P-90D170) polarity guard assembly is
installed on the right key bracket (Fig. 4) with
screw provided or an 819041971 (P-90D197) polarity
guard assembly (adhesive backed) is installed
wherever space permits. Connect per Table D.
Fig.
3-D-180656
Kit of Parts for Wall Mounting
Arrangements
3.06
The 830DM and 2830DM telephone set employs
the 2A1 matrix block in place of polarity
guard described in 3.05. This unit provides eight
polarity guard circuits. One polarity guard circuit
Page
3
Scannea
Frarik Rarrell, (Cow6oy FrariR) Castle RocK Coloraao
Oet05,