View error code history
Turn the selector wheel to highlight
8.6 Error History
. Press
OK
.
RESET
BACK
OK
19°
25/07/18 09:00
80°
60°
ECO
AUTO
Press OK to enter Menu
1.5 bar
From the controller Home screen,
press the
BACK
and
OK
buttons
at the same time for 7 seconds
1
Technical area
Language, date and time
Complete Menu
Configuration Wizard
Service
Faults
The screen below then appears.
Turn the selector wheel to highlight
Complete Menu
. Press
OK
. It takes
a while to load the menu.
3
Menu
5
6
7
8
9
Zone 2 Parameters
Zone 3 Parameters
< Not Available >
Service Param
< Not Available >
Error History
8.6
8.6.0
8.6.1
Last 10 Errors
Reset Error List
Turn the selector wheel to highlight
8 Service Param
. Press
OK
.
4
5
Insert Code
007
Save
Insert technical code
Turn the selector wheel to highlight
007
as the Technical Code. Press
OK
to Save.
2
Option
8.6.0
Last 10 Errors
is highlighted.
Press
OK
.
6
A survey of the last 10 Errors appears.
An example of an error message.
7
Last 10 Errors
8.6.0
Fault 6
140
Dynamic Pressure Check Failed
10:14 20/08/18
Service Param
8
8.2
8.3
8.4
8.5
8.6
Boiler
Boiler Temperature
Storage
Service
Error History
Error codes
A detected failure is indicated on the display in blocking or error messages.
ERROR
CODE
ERROR DESCRIPTION
CHECKS
101
Overheat
Temperature rise too fast. Check correct circulation of the water and
pump
102
Pressure Sensor Error
Check water pressure on analogue gauge
Check the sensor
Check wiring harness not shorting to earth
Check the connection plug on top of sensor and PCB
104
Flow Check Failed
Check pump is spinning via de-blocking centre screw
Check PWM pump connection pins, cable and PCB connection CN9
108
Pressure < Pmin (< 0.5 bar), Filling needed
Check water pressure on analogue gauge
1P4
Pressure < Pmin (0.5 - 0.8 bar), Filling needed
Check water pressure on analogue gauge